IM26TS TE Connectivity, IM26TS Datasheet
![RELAY, PCB, DPCO, 12VDC](/photos/19/26/192667/42265269_sml.jpg)
IM26TS
Specifications of IM26TS
Related parts for IM26TS
IM26TS Summary of contents
Page 1
IM Relay 108-98001 • Sep. 07 Rev. G • ECOC: JM10 AXICOM Telecom-, Signal and RF Relays ...
Page 2
AXICOM Telecom-, Signal and RF Relays IM Relay UL 508 File No. E 111441 UL 60950 IEC/EN60950 IEC Ref. Cert. No. 3270 All specifications subject to change. Consult Tyco Electronics for latest specifications. Disclaimer While Tyco Electronics has made every ...
Page 3
AXICOM Telecom-, Signal and RF Relays IM Relay Slim line AND low profile 2 pole telecom/signal relay, polarized Through Hole Types (THT), standard version with 5.08 mm, narrow version with 3.2 mm between the terminal rows or Surface Mount Type ...
Page 4
AXICOM Telecom-, Signal and RF Relays IM Relay Dimensions IM THT Standard mm inch L 10.00 ± 0.08 0.393 ± 0.003 W 6.00 ± 0.08 0.236 ± 0.003 H 5.65 – 0.20 0.222 – 0.008 T 3.2 0.125 T1 N/A ...
Page 5
AXICOM Telecom-, Signal and RF Relays IM Relay Coil Operating Range 3.4 3 max. 2.8 2 2.4 max. 2 max. 1.6 ...
Page 6
AXICOM Telecom-, Signal and RF Relays IM Relay Coil Data (values at 23 °C) Nominal Operate/set voltage range voltage U nom Minimum Maximum voltage U voltage U min Vdc Vdc Standard Version THT Standard non-latching 1 coil 1.5 1.13 3 ...
Page 7
AXICOM Telecom-, Signal and RF Relays IM Relay Coil Data (values at 23 °C) Nominal Operate/set voltage range voltage U nom Minimum Maximum voltage U voltage U min Vdc Vdc Latching Version THT Standard latching 1 coil 1.5 1.13 3 ...
Page 8
AXICOM Telecom-, Signal and RF Relays IM Relay Coil Data (values at 23 °C) Nominal Operate/set voltage range voltage U nom Minimum Maximum voltage U voltage U min Vdc Vdc High Sensitive Version SMT Gull Wings non-latching 1 coil 3 ...
Page 9
... Further coil versions are available on request. 108-98001 Rev. G Ordering Information Coil Relay Resistance code Ω / ± 180 IM21GR 2-1462039-6 405 IM22GR 2-1462039-7 500 IM23GR 2-1462039-9 2880 IM26GR 3-1462039-1 180 IM21TS 1-1462039-5 405 IM22TS 2-1462039-8 500 IM23TS 3-1462039-0 2880 IM26TS 3-1462039-2 Tyco part number ...
Page 10
AXICOM Telecom-, Signal and RF Relays IM Relay Contact Data Number of contacts and type Contact assembly Contact material Limiting continuous current at max. ambient temperature Maximum switching current Maximum swichting voltage Maximum switching capacity Thermoelectric potential Minimum switching voltage ...
Page 11
AXICOM Telecom-, Signal and RF Relays IM Relay Insulation Insulation resistance at 500 Vdc Dielectric test voltage (1 min) between coil and contacts between adjacent contact sets between open contacts Surge voltage resistance according to Telcordia TR-NWT-001089 (2/10 µs) between ...
Page 12
AXICOM Telecom-, Signal and RF Relays IM Relay Recommended Soldering Conditions Soldering conditions according IEC 60058-2-58 and IPC/JEDEC J-STD-020B sec 240 °C 180 °C 130 °C 100 °C Time (s) Recommended reflow soldering profile Time (s) Resistance ...
Page 13
AXICOM Telecom-, Signal and RF Relays IM Relay Packing Reel dimension All specifications subject to change. Consult Tyco Electronics for latest specifications. 108-98001 Rev. G Dimensions in mm Tube for THT version 50 relays per tube 1‘000 relays per box ...
Page 14
AXICOM Telecom-, Signal and RF Relays IM Relay IM Relays 4th generation slim line – low profile polarized 2 c/o telecom signal relay with bifurcated contacts, available as non latching or latching relay with 1 coil. Nominal voltage range from ...
Page 15