M8134-HC-12P2 TE Connectivity, M8134-HC-12P2 Datasheet

no-image

M8134-HC-12P2

Manufacturer Part Number
M8134-HC-12P2
Description
M8134-HC-12P2=CONTACT AU PLT.
Manufacturer
TE Connectivity
Datasheets

Specifications of M8134-HC-12P2

Rohs Compliant
YES
Socket Length (mm [in])
4.06 [0.160]
Sealant
Without
Proprietary Name
HOLTITE
Recommended Hole Size (mm [in])
2.08 [0.082]
Mating Pin Dia. Range (mm [in])
0.89 – 1.14 [0.035 – 0.045]
Spring Material
Beryllium Copper
Contact Spring Plating
Gold
Contact Base Material
Beryllium Copper
Insertion Method
Hand/Semi-Automatic
Government/industry Qualification
Yes
Government/industry Part Number
M83505/6-004
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Application
Production
Packaging Method
Loose Piece
1.
1.1.
1.2.
1.3.
2.
2.1.
2.2.
3.
3.1.
3.2.
©2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. Company
All Rights Reserved
TE logo is a trademark.
SCOPE
Content
This specification covers performance, tests and quality requirements for the TE Connectivity (TE)
AUGAT* HOLTITE* Sockets. These sockets are designed to be press-fit into a plated through hole of a
printed circuit board. This unique design allows the plated through hole to become a component socket.
The sockets are designed to accept a .016 to .021 inch round lead (5P), .011 X .018 inch rectangular
lead (5P), .020 to .030 inch round lead (6P), .025 to .035 inch round lead (8P) and .035 to .045 inch
round lead (12P).
Qualification
When tests are performed on the subject product line, procedures specified in Figure 1 shall be used.
All inspections shall be performed using the applicable inspection plan and product drawing.
Qualification Test Results
Successful qualification testing on the subject product line has been completed. The Qualification Test
Report number for this testing is 501-500. This documentation is on file at and available from
Engineering Practices and Standards (EPS).
APPLICABLE DOCUMENTS
The following documents form a part of this specification to the extent specified herein. Unless
otherwise specified, the latest edition of the document applies. In the event of conflict between the
requirements of this specification and the product drawing, the product drawing shall take precedence.
In the event of conflict between the requirements of this specification and the referenced documents,
this specification shall take precedence.
TE Documents
!
!
Commercial Standard
EIA-364: Electrical Connector/Socket Test Procedures Including Environmental Classifications
REQUIREMENTS
Design and Construction
Product shall be of the design, construction and physical dimensions specified on the applicable product
drawing.
Materials
Materials used in the construction of this product shall be as specified on the applicable product
drawing.
109-197: TE Test Specifications vs EIA and IEC Test Methods
501-500: Qualification Test Report
| Indicates change
*Trademark
Product
Specification
AUGAT* HOLTITE* Sockets
For latest revision, visit our website at www.te.com/documents.
For Regional Customer Service, visit our website at www.te.com
Other products, logos, and company names might be trademarks of their respective owners.
108-1979
11Mar11 Rev B
1 of 5
LOC B

Related parts for M8134-HC-12P2

M8134-HC-12P2 Summary of contents

Page 1

... Content This specification covers performance, tests and quality requirements for the TE Connectivity (TE) AUGAT* HOLTITE* Sockets. These sockets are designed to be press-fit into a plated through hole of a printed circuit board. This unique design allows the plated through hole to become a component socket. ...

Page 2

Ratings ! Current: 5 amperes using an .062 inch thick glass epoxy, Type FR4, with 2 ounce copper, plated, with electroplated (.001 inch minimum) copper and electroplated tin/lead (.0003 inch minimum) plated through holes. ! Temperature: • Gold contacts: ...

Page 3

Test Description Insertion force. Withdrawal force. Contact retention. Thermal shock. Humidity-temperature cycling. Salt spray. Temperature cycling. Shall meet visual requirements, show no physical damage, and meet requirements of additional NOTE tests as specified in the Product Qualification and Requalification Test ...

Page 4

Product Qualification and Requalification Test Sequence Test or Examination Examination of product Low level contact resistance Insulation resistance Temperature rise vs current Vibration Durability Insertion force Withdrawal force Contact retention Thermal shock Humidity-temperature cycling Salt spray Temperature cycling (a) ...

Page 5

QUALITY ASSURANCE PROVISIONS 4.1. Qualification Testing A. Specimen Selection Specimens shall be prepared in accordance with applicable Instruction Sheets and shall be selected at random from current production. All test groups shall each consist of a minimum of 32 ...