UWR-12/1250-D5A Murata Power Solutions Inc, UWR-12/1250-D5A Datasheet - Page 3

no-image

UWR-12/1250-D5A

Manufacturer Part Number
UWR-12/1250-D5A
Description
DC/DC TH 20W 5-12V Single A
Manufacturer
Murata Power Solutions Inc
Datasheet

Specifications of UWR-12/1250-D5A

Rohs Compliant
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UWR-12/1250-D5A
Manufacturer:
DATEL
Quantity:
78
Part Number:
UWR-12/1250-D5A
Manufacturer:
DATEL
Quantity:
134
Performance/Functional Specifications
Typical @ T
tion
meet all listed
added
can cause permanent damage to the converter.
DATEL Applications Engineering for details.
Input Voltage Range:
Input Current
Input Filter Type
Overvoltage Shutdown:
Reverse-Polarity Protection
On/Off (Sync.) Control (Pin 4)
V
Temperature Coefficient
Ripple/Noise (20MHz BW)
Line/Load Regulation
Efficiency
Isolation Voltage
Isolation Capacitance
Current Limiting
Overvoltage Protection
Transient Response (50% load step)
Switching Frequency
Operating Temperature (Ambient):
Storage Temperature
Flammability
Dimensions
Shielding
Case Connection:
Case Material
Pin Material
Weight
OUT
D5A Models
D12A Models
D48A/D48E Models
D5A Models
D12A Models
D48A and /D48E Models
Without Derating
With Derating
D5A, D12A Models
D48A, D48E Models
enamel finish and plastic baseplate
These converters require a minimum 10% loading to maintain specified regulation. Opera-
Application-specific internal input/output filtering can be recommended and perhaps
Applying a voltage to the Control pin when no input power is applied to the converter
"D48A" models have BASIC, all other models have Functional insulation.
Devices can be screened or modified for higher guaranteed isolation voltages. Contact
Except for 3.3V outputs which have no protection.
Accuracy (50% load)
A
= +25°C under nominal line voltage and full-load conditions, unless noted.
under no-load conditions will not damage these devices; however they may not
internally upon request. Contact DATEL Applications Engineering for details.
specifications.
Dynamic Characteristics
Environmental
Physical
Output
Input
4.7-7.5 Volts (5V nominal)
9-36 Volts (24V nominal)
18-75/36-72 Volts (48V nominal)
See Ordering Guide
Pi (C-type for D5A models)
10 Volts
40 Volts
80 Volts
Yes (Instantaneous, 10A maximum)
TTL high = off, low (or open) = on
±1%, maximum
±0.02% per °C
See Ordering Guide
See Ordering Guide
See Ordering Guide
1500Vdc guaranteed
550pF
Auto-recovery
Zener/transorb clamp, magnetic feedback
200μsec max. to ±1.5% of final value
165kHz (±15kHz)
–40 to +40/50/55/65°C (Model dependent)
to +100°C (See Derating Curves)
-40 to +105°C
UL94V-0
2" x 2" x 0.45" (51 x 51 x 11.4mm)
5-sided
Pin 2 (–V
Pin 1 (+V
Corrosion resistant steel with
non-conductive, epoxy-based, black
RoHS: Gold-plated copper alloy
Non-RoHS: Tin over copper alloy
2.7 ounces (76.5 grams)
IN
IN
www.murata-ps.com
)
)
Single Output, High Reliability, 2" x 2", 14-20 Watt, DC/DC Converters
Floating Outputs
Since these are isolated DC/DC converters, their outputs are "floating."
Users may ground either the Common (pin 7) for normal usage or the posi-
tive side (+Output, pin 6) to effectively reverse the output polarity.
Filtering and Noise Reduction
All A-Series UWR 14-20 Watt DC/DC Converters achieve their rated ripple
and noise specifications without the use of external input/output capaci-
tors. In critical applications, input/output noise may be further reduced by
installing electrolytic capacitors across the input terminals and/or low-ESR
tantalum or electrolytic capacitors across the output terminals. The caps
should be located as close to the power converters as possible. Typical
values are listed below. In many applications, using values greater than
those listed will yield better results.
In critical, space-sensitive applications, DATEL may be able to tailor the
internal input/output filtering of these units to meet your specific require-
ments. Contact our Applications Engineering Group for additional details.
Input Voltage:
Input Reverse-Polarity Protection
Output Overvoltage Protection:
Output Current
Storage Temperature
Lead Temperature
These are stress ratings. Exposure of devices in excess of these conditions may
adversely affect long-term reliability. Proper operation under conditions other than those
listed in the Performance/Functional Specifications Table is not implied.
To Reduce Input Ripple
To Reduce Output Ripple
"D5A" Models
"D12A" Models
"D48A" and "D48E" Models
3.3V Outputs
5V/5.2V Outputs
12V Outputs
15V Outputs
D5A Models
D12A Models
D48A Models
3.3V Outputs
5V/5.2V Outputs
12/15V Outputs
Technical enquiries email: sales@murata-ps.com, tel:
Absolute Maximum Ratings
TECHNICAL NOTES
47μF, 16V
20μF, 50V
20-50μF, 100V
100μF, 6V, Low ESR
47μF, 10V, Low ESR
22μF, 20V, Low ESR
MDC_UWR14-20 Series.B02 Page 3 of 6
11 Volts
44 Volts
88 Volts
Current must be <10A. Brief
duration only. Fusing recommended.
No protection
6.8 Volts, limited duration
15 Volts, limited duration
18 Volts, limited duration
Current limited. Max. current and
short-circuit duration are model
dependent
–40 to +105°C
See soldering guidelines
UWR Series
+1 508 339 3000

Related parts for UWR-12/1250-D5A