CS4338-KSZ Cirrus Logic Inc, CS4338-KSZ Datasheet - Page 22

IC DAC 24BIT 96KHZ 96DB 8-SOIC

CS4338-KSZ

Manufacturer Part Number
CS4338-KSZ
Description
IC DAC 24BIT 96KHZ 96DB 8-SOIC
Manufacturer
Cirrus Logic Inc
Datasheet

Specifications of CS4338-KSZ

Number Of Converters
2
Package / Case
8-SOIC
Number Of Bits
24
Data Interface
Serial
Voltage Supply Source
Single Supply
Power Dissipation (max)
104mW
Operating Temperature
-10°C ~ 70°C
Mounting Type
Surface Mount
Number Of Dac Outputs
2
Conversion Rate
96 KSPS
Resolution
16 bit
Interface Type
Serial
Supply Voltage (max)
5.5 V
Supply Voltage (min)
4.75 V
Maximum Operating Temperature
+ 70 C
Mounting Style
SMD/SMT
Maximum Power Dissipation
104 mW
Minimum Operating Temperature
- 10 C
Supply Current
15 mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Settling Time
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
598-1048-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CS4338-KSZ
Manufacturer:
CRYSTAL
Quantity:
26 674
Part Number:
CS4338-KSZ
Manufacturer:
CIRRUS
Quantity:
20 000
Part Number:
CS4338-KSZR
Manufacturer:
CIRRUS
Quantity:
20 000
22
5. PARAMETER DEFINITIONS
Total Harmonic Distortion + Noise (THD+N)
Dynamic Range
Interchannel Isolation
Interchannel Gain Mismatch
Gain Error
Gain Drift
6. REFERENCES
1. "How to Achieve Optimum Performance from Delta-Sigma A/D & D/A Converters" by Steven Harris. Paper
2. CDB4334/5/8/9 Evaluation Board Datasheet
The ratio of the rms value of the signal to the rms sum of all other spectral components over the specified
bandwidth (typically 10Hz to 20kHz), including distortion components. Expressed in decibels.
The ratio of the full scale rms value of the signal to the rms sum of all other spectral components over the
specified bandwidth. Dynamic range is a signal-to-noise measurement over the specified bandwidth made
with a -60 dBFS signal. 60 dB is then added to the resulting measurement to refer the measurement to full
scale. This technique ensures that the distortion components are below the noise level and do not effect the
measurement. This measurement technique has been accepted by the Audio Engineering Society, AES17-
1991, and the Electronic Industries Association of Japan, EIAJ CP-307.
A measure of crosstalk between the left and right channels. Measured for each channel at the converter's
output with all zeros to the input under test and a full-scale signal applied to the other channel. Units in deci-
bels.
The gain difference between left and right channels. Units in decibels.
The deviation from the nominal full-scale analog output for a full-scale digital input.
The change in gain value with temperature. Units in ppm/°C.
presented at the 93rd Convention of the Audio Engineering Society, October 1992.