CS4365-CQZ Cirrus Logic Inc, CS4365-CQZ Datasheet - Page 39

IC DAC 6CH 114DB 192KHZ 48LQFP

CS4365-CQZ

Manufacturer Part Number
CS4365-CQZ
Description
IC DAC 6CH 114DB 192KHZ 48LQFP
Manufacturer
Cirrus Logic Inc
Datasheet

Specifications of CS4365-CQZ

Package / Case
48-LQFP
Number Of Bits
24
Data Interface
Serial
Number Of Converters
6
Voltage Supply Source
Analog and Digital
Power Dissipation (max)
390mW
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Conversion Rate
216 KSPS
Resolution
24 bit
Interface Type
Serial
Operating Supply Voltage
5 V
Operating Temperature Range
+ 85 C
Maximum Power Dissipation
390 mW
Mounting Style
SMD/SMT
Number Of Dac Outputs
6
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
598-1779 - EVALUATION BOARD FOR CS4365
Settling Time
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
598-1060

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CS4365-CQZ
Manufacturer:
NS
Quantity:
301
Part Number:
CS4365-CQZ
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
Part Number:
CS4365-CQZR
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
DS670F2
6.7.2 Channel A Volume = Channel B Volume (Px_A=B)
6.7.3 Single Volume Control (SNGLVOL)
6.8
6.8.1 Soft Ramp and Zero Cross CONTROL (SZC)
SZC1
1
7
Ramp and Mute (address 08h)
Default = 0
0 - Disabled
1 - Enabled
Function:
The AOUTAx and AOUTBx volume levels are independently controlled by the A and the B Channel Vol-
ume Control Bytes when this function is disabled. The volume on both AOUTAx and AOUTBx are deter-
mined by the A Channel Attenuation and Volume Control Bytes (per A-B pair), and the B Channel Bytes
are ignored when this function is enabled.
Default = 0
0 - Disabled
1 - Enabled
Function:
The individual channel volume levels are independently controlled by their respective Volume Control
Bytes when this function is disabled. The volume on all channels is determined by the A1 Channel Volume
Control Byte, and the other Volume Control Bytes are ignored when this function is enabled.
Default = 10
00 - Immediate Change
01 - Zero Cross
10 - Soft Ramp
11 - Soft Ramp on Zero Crossings
Function:
Immediate Change
When Immediate Change is selected, all level changes will take effect immediately in one step.
Zero Cross
Zero Cross Enable dictates that signal-level changes, either by attenuation changes or muting, will occur
on a signal zero crossing to minimize audible artifacts. The requested level change will occur after a tim-
eout period between 512 and 1024 sample periods (10.7 ms to 21.3 ms at 48 kHz sample rate) if the signal
does not encounter a zero crossing. The zero cross function is independently monitored and implemented
for each channel.
Soft Ramp
Soft Ramp allows level changes, both muting and attenuation, to be implemented by incrementally ramp-
ing, in 1/8 dB steps, from the current level to the new level at a rate of 1 dB per 8 left/right clock periods.
SZC0
6
0
RMP_UP
5
1
RMP_DN
1
4
PAMUTE
3
1
DAMUTE
2
1
MUTE_P1
0
1
MUTE_P0
CS4365
0
0
39