794955-1 TE Connectivity, 794955-1 Datasheet - Page 5

no-image

794955-1

Manufacturer Part Number
794955-1
Description
CONTACT, PIN, 24-18AWG, CRIMP
Manufacturer
TE Connectivity
Series
PEr
Datasheets

Specifications of 794955-1

Connector Type
Contact, Crimp
Current Rating
9A
Contact Plating
Tin
Contact Material
Brass
Pitch Spacing
0.165"
Body Material
Brass
Rohs Compliant
Yes
Contact Gender
Pin
Product Type
Contact
Termination Method To Wire/cable
Crimp
Strain Relief
With
Ul File Number
E28476
Csa File Number
208567
Contact Current Rating, Max (a)
9
Operating Voltage Reference
AC
Operating Voltage (vac)
600
Wire/cable Size (awg)
18 – 24
Wire/cable Size (mm²)
0.2 – 0.8
Strain Relief Type
Insulation Crimp
Length (x-axis) (mm [in])
16.80 [0.6614]
Contact Type
Pin
Contact Base Material
Brass
Contact Plating, Mating Area, Material
Pre-Tin
Contact Plating, Mating Area, Thickness (µm [?in])
2.54 [100]
Contact Design
Formed Pin
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Agency/standard
UL, CSA
Ul Rating
Recognized
Operating Temperature (°c [°f])
-40 – +105 [-40 – +221]
Applies To
Wire/Cable
Application Use
Wire-to-Wire
Contact Transmits (typical Application)
Signal (Data)
Packaging Method
Strip
For Use With
VAL-U-LOK Series Connector System

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
794955-1
Manufacturer:
TE
Quantity:
40 838
4.
4.1.
4.2.
4.3.
4.4.
Rev B
QUALITY ASSURANCE PROVISIONS
Qualification Testing
A.
B.
Requalification Testing
If changes significantly affecting form , fit or function are m ade to the product or m anufacturing process,
product assurance shall coordinate requalification testing, consisting of all or part of the original testing
sequence as determ ined by developm ent/product, quality and reliability engineering.
Acceptance
Acceptance is based on verification that the product m eets the requirem ents of Figure 1. Failures
attributed to equipm ent, test setup or operator deficiencies shall not disqualify the product. If product
failure occurs, corrective action shall be taken and specim ens resubm itted for qualification. Testing to
confirm corrective action is required before resubm ittal.
Quality Conform ance Inspection
The applicable quality inspection plan shall specify the sam pling acceptable quality level to be used.
Dim ensional and functional requirem ents shall be in accordance with the applicable product drawing
and this specification.
Specim en Selection
Specim ens shall be prepared in accordance with applicable Instruction Sheets and shall be
selected at random from current production. Each test group shall consist of a m inim um of 5
specim ens.
Test Sequence
Qualification inspection shall be verified by testing specim ens as specified in Figure 2.