5747959-1 TE Connectivity, 5747959-1 Datasheet - Page 3

D SUB SHELL, RECEPTACLE, SIZE 5, STEEL

5747959-1

Manufacturer Part Number
5747959-1
Description
D SUB SHELL, RECEPTACLE, SIZE 5, STEEL
Manufacturer
TE Connectivity
Series
AMPLIMITE HDP-20r
Datasheets

Specifications of 5747959-1

Connector Type
D Sub
Connector Shell Size
5
Connector Body Material
Metal
Body Material
Steel
Gender
Receptacle
Rohs Compliant
Yes
Product Type
Connector
Product Series
HDP-20 (Crimp Snap)
Mating Connector Lock
With
Mating Connector Lock Type
Jackscrews
Shell Size
5
Shell Type
Full Metal Shell
Grounding Indents
Without
Grade
Standard
Enclosure Material
PVC
Jackscrew Material
Zinc Alloy
Color
Black
Shell Material
Steel
Shield Material
Steel
Shielded
Yes
Number Of Positions
50
Pre-assembled
No
Cable Insulation Diameter (mm [in])
5.84 – 14.28 [0.230 – 0.562]
Shell Plating
Tin over Copper
Shield Plating
Tin
Insert Material
Thermoplastic
Insert Flammability Rating
UL 94V-0
Cable Diameter (max.) (mm [in])
11.43 [0.450]
Preloaded
No
Contact Size
20
Enclosure
With
Connector Style
Receptacle
Housing Material
Nylon
Ul Flammability Rating
UL 94V-0
Housing Color
Black
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Packaging Method
Bulk
Packaging Quantity
100
For Use With
HDP-20 Series D Sub Connectors
Tem perature rise vs current.
Vibration, random .
Mechanical shock.
Durability.
Mating force.
Unm ating force.
Contact insertion force.
Rev F
Test Description
30°C m axim um tem perature rise at
specified current.
No discontinuities of 1 m icrosecond
or longer duration.
See Note.
No discontinuities of 1 m icrosecond
or longer duration.
See Note.
See Note.
Size Posn
Size Posn
13.3 N [3 lbf] m axim um per contact. EIA-364-5.
1
2
3
4
5
1
2
3
4
5
15
25
37
50
15
25
37
50
9
9
Figure 1 (continued)
MECHANICAL
Requirem ent
12.5 [2.8]
20.9 [4.7]
34.7 [7.8]
51.6 [11.6] 177.9 [40]
69.4 [15.6] 195.7 [44]
12.5 [2.8]
20.9 [4.7]
34.7 [7.8]
51.6 [11.6] 177.9 [40]
69.4 [15.6] 195.7 [44]
(N [lbf] m axim um )
W ithout
(N [lbf] m axim um )
W ithout
Ground Indents
Ground Indents
133.4 [30]
146.8 [33]
164.6 [37]
133.4 [30]
146.8 [33]
164.6 [37]
W ith
W ith
EIA-364-70, Method 1.
Stabilize at a single current level
until 3 readings at 5 m inute intervals
are within 1°C.
See Figure 4.
EIA-364-28, Test Condition V,
Condition F.
Subject m ated specim ens to 20.71
G's rm s between 50 to 2000 Hz.
Fifteen m inutes in each of 3
m utually perpendicular planes.
See Figure 5.
EIA-364-27, Method A.
Subject m ated specim ens to 50 G's
half-sine shock pulses of 11
m illiseconds duration. Three shocks
in each direction applied along 3
m utually perpendicular planes, 18
total shocks.
See Figure 5.
EIA-364-9.
Mate and unm ate gold flash
specim ens for 100 cycles, and 30
ìin gold specim ens for 500 cycles
at a m axim um rate of 200 cycles
per hour.
EIA-364-13.
Measure force necessary to m ate
specim ens at a m axim um rate of
25.4 m m [1 in] per m inute.
EIA-364-13.
Measure force necessary to unm ate
specim ens at a m axim um rate of
25.4 m m [1 in] per m inute.
Measure force necessary to insert
contact into housing.
Procedure
108-40005
3 of 10

Related parts for 5747959-1