2-1103107-3 TE Connectivity, 2-1103107-3 Datasheet - Page 24

INSERT, FEMALE, CRIMP, 15WAY

2-1103107-3

Manufacturer Part Number
2-1103107-3
Description
INSERT, FEMALE, CRIMP, 15WAY
Manufacturer
TE Connectivity
Series
HN.Dr
Datasheet

Specifications of 2-1103107-3

Connector Type
Rectangular Power
Gender
Receptacle
No. Of Contacts
15
No. Of Rows
3
Contact Gender
Socket
Connector Mounting
Panel
Connector Shell Size
2
Contact Termination
Crimp
Rohs Compliant
Yes
Contact Material
Copper Alloy
Product Type
Insert
Product Size
2
Power Circuit Voltage (v)
250
Power Circuit Current (a)
10
Pollution Degree
3
Insert Style
Socket
Contact Configuration
Crimp Terminal
Number Of Poles
15+PE
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Packaging Method
Loose Piece
Packaging Quantity
5
Lead Free Status / Rohs Status
 Details
22
HTS Industrie Steckverbinder
Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten Tyco Electronics Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
All specifications subject to change. Consult Tyco Electronics for latest design specifications.
*) chosen voltage values
**) the / dash is for a 3-phase system with 4 lines. The lower value is for phase to neutral, the higher value is for phase to phase
Measurement of Clearances
3-phase systems
230/400**
277/480**
400/690**
rated surge voltage
1000
of the power supply *) in V
> 2000 m
height
rated voltage
NN
single systems
120 up to 240
in the centre
Diagram for the Determination of Clearances
utilities at the feed of
(surge category lV)
the installation
Rated Surge Voltage for Utilities
multiply L with height correction
12
factor acc. to table 2 b
4
6
8
minimum clearance L
of the power supply
rated surge voltage
acc. to table 2 a
acc. to table 1
rated voltage
clearance L
in mm
utilities as part of a
(surge category lll)
Rated Surge Voltage in kV (1,2/50ms) for
fixed installation
2,5
4
6
8
(surge category ll)
connection to
installations
utilites for
fixed
normally 3, but acc. to EN 61984
1,5
2,5
a smaller class may be chosen
4
6
HTS Heavy Duty Connectors
protection class of IP 54
if the housing has a
degree of pollution
surge categories,
normally III
(surge category l)
protected utilities
Specially
0,8
1,5
2,5
4

Related parts for 2-1103107-3