B0603R104KCT MULTICOMP, B0603R104KCT Datasheet - Page 5

CAPACITOR CERAMIC, 0.1UF, 16V, X7R, 0603

B0603R104KCT

Manufacturer Part Number
B0603R104KCT
Description
CAPACITOR CERAMIC, 0.1UF, 16V, X7R, 0603
Manufacturer
MULTICOMP
Datasheet

Specifications of B0603R104KCT

Dielectric Characteristic
X7R
Capacitance
0.1µF
Capacitance Tolerance
± 10%
Voltage Rating
16VDC
Capacitor Case Style
0603
No. Of Pins
2
Capacitor Mounting
SMD
Rohs Compliant
Yes
Temperature
Characteristic
of Capacitance
Solderabiliy
Leaching
Soldering
to heat
Nickel Barrier
Multilayer Ceramic Capacitors
Item
Capacitance
Appearance
External
Change
(∆ C/C)
DF
IR
X7R/X5
X7R, X5R, Y5V, Z5U : (Maximum Value)
Z5U
New solder to over 95% of termination
No mechanical Damage
NPO
NPO:
100,000MW minimum or R x C ≥1000W
x F (Whichever is smaller)
X7R, X5R, Y5V, Z5U:
10,000MW minimum or R x C ≥1000W
x F (Whichever is smaller)
NPO -55 ~ +125°C
Z5U
Y5V
X7R -55 ~ +125°C
X5R
Y5V -55 ~ +125°C
TC
X7R/
R
X5R
Z5U
Y5V
T.C.
PS: C : Nominal Capacitance (pF)
NPO: C ≥30pF : Q ≥ 1000
Temperature
-55 ~ +125°C
C<30pF:Q ≥ 400 + 20°C
-55 ~ +85°C
Temperatures Coefficient
Operating
±2.5% or ±0.25 pF maximum
2.5%
4.0%
5.0%
50V
Performance
(Whichever is larger)
≥ ≥
3.0%
7.5%
25V
±7.5%
-
±20%
±20%
0 ±30 (ppm/°C)
+22% ~ -82%
+22% ~ -56%
Change (DC)
Capacitance
3.5%
9.0% 12.5%
16V
±15%
±15%
-
≤ ≤ 10V
5.0%
Page 5
-
The temperature coefficient is determined using the
capacitance measured in step 3 as a reference. Test the
specimen from step 1through step 5, the capacitance shall
be within the specified tolerance for the capacitance
coefficient and capacitance change as left table.
Completely soak both terminal electrodes in
solder at specified temperature for 3 ±0.5 second
a. For Tin-Lead Sn/Pb) Termination product:
235 ±5°C.
b. For Lead-free (Pure Sn) Termination
product: 245 ±5°C.
Completely soak both terminal electrodes in solder at 270
±5°C for 40 ±1second.
Completely immerse both
terminations in solder at 270 ±5°C for 10 ±3 second.
Leave the capacitors in ambient condition for 2 4 ±2 hours
before measurement.
*Preconditioning: F(only for Class 2):
Perform a heat treatment at 150 +0-10°C for one hour and
then let sit for 24 ±2 hours at room temperature.
Perform the initial measurement.
Code
1
2
3
4
5
Test or Inspection Method
Minimum Operation Temperature ±2°C
Minimum Operation Temperature ±2°C
Base Temperature (25°C) ±2°C
Base Temperature (25°C) ±2°C
Base Temperature (25°C) ±2°C
Temperature Coefficient
27/04/06 V1.0

Related parts for B0603R104KCT