GLCB01A4J Honeywell, GLCB01A4J Datasheet - Page 6

Basic / Snap Action / Limit Switches SW 1NC 1NO SPDT 6A Side Rotary w/Rod

GLCB01A4J

Manufacturer Part Number
GLCB01A4J
Description
Basic / Snap Action / Limit Switches SW 1NC 1NO SPDT 6A Side Rotary w/Rod
Manufacturer
Honeywell
Type
Limit Switchr
Datasheet

Specifications of GLCB01A4J

Pole Throw Configuration
DPST
Switch Function Configuration
N.O./N.C.
Current Rating (max)
6A
Operating Temp Range
-40C to 85C
Actuator
Plunger, Pin
Operating Force
0.12 N
Contact Form
SPDT - 1 NC / 1 NO
Ip Rating
IP 66
Nema Rating
1, 4, 12, 13
Contact Rating
10 Amps
Termination Style
Quick Connect
Ingress Protection
IP66 / NEMA 1, 4, 12, 13
Lead Free Status / Rohs Status
Compliant
Ordering :
6
GLE
EN 50047 Compatible
3 conduit metal
standard
Technical data
Mechanical life up to 15 million operations
Degree of
protection
Temperature
range
Storage :
Approvals
Vibration
Shock
12,5
(.49)
(.47)
12
GLE
24,75
(.97)
(1.18)
30
Conduit thread
conduit
thread
(.12)
13,75
R 2,15
(.54)
Example : GLE B 01 B
2,5
(.1)
3
(.08)
IP 67 (wobble: IP 66)
NEMA/UL
type 1, 4, 12, 13
Operating: -40°C to +85°C
-40°F to +185°F
Storage: -40°C to +85°C
-40°F to +185°F
IEC60947-5-1
EN60947-5-1
AC15 A300
DC13 Q300
UL & CSA
10 g conforming to
IEC 68-2-6
50 g conforming to
IEC 68-2-27
Terminal marking to
EN 50013
X
A
B
C
(1.65)
(2.05)
(2.24)
(2.56)
(1.57)
¯ (.9)
= 1/2” NPT
= PG 13,5
= 20 mm
(.87)
(.79)
¯ 23
42
22
20
52
57
65
40
23,8
(.94)
(2.37)
60
adaptor
(.16)
4
GLS Series -
* Positive opening to IEC/EN60947-5-1-3
Snap-Action Contacts
1 NORMALLY CLOSED /
1 NORMALLY OPEN
(F.P.)
(O.P.)
(R.P.)
* Point from which the positive opening is assured
OP 35,8
OP 28
© 2004 Honeywell International Inc. All rights reserved.
31 mm
39,25
Circuit closed
26°
14,5°
26
25
01
26°
07
(D.T.)
(
(T.T.)
*
DT=
1,3
14,5°
)
FP
OT
(max.)
DT=
0,9
11,5°
11,5°
54°
70° min.
54° 70°
Low Energy Contacts
13
Zb
21
FP
37,1
TT
min.
28,9 RP
TT
Note: See page 9
14
22
1 NORMALLY CLOSED/
Slow-Action Contacts
BREAK BEFORE MAKE
1 NORMALLY OPEN
(F.P.)
(O.P.)
(R.P.)
OP 28
34,5
26°
31 mm
21 mm
18 mm
17 mm
15 mm
39,25
35,8
34,2
27
25
26°
26°
03
(D.T.)
(O.P.2) 39°
(T.T.) 70° min.
33
21
13
FP
OP
*
FP
* 27,2
OT (max.)
39°
FP
OT
(max.)
39°
Zb
70°
min.
70°
min.
22
14
(F.P.)
(O.P.)
(R.P.)
(
*
21-22
13-14
)
Slow-Action
Contacts
MAKE BEFORE BREAK
1 NORMALLY CLOSED/
FP
26°
50,5°
21 mm
18 mm
17 mm
15 mm
31 mm
26,2
28
27
25
39,25
35,8
32,8
34,2
26°
04
34
39°
21
13
Zb
(D.T.)
(O.P.2) 39°
(T.T.)
FP
*
OT (max.)
*
FP
OP
FP
OT
(max.)
50,5°
*
22
14
70° min.
TT
70°
min.
XX

Related parts for GLCB01A4J