E2E2-X2B2-M1 Omron, E2E2-X2B2-M1 Datasheet - Page 2

Proximity Sensors E2E2-X2B2 W/ M12 CO NNECTOR

E2E2-X2B2-M1

Manufacturer Part Number
E2E2-X2B2-M1
Description
Proximity Sensors E2E2-X2B2 W/ M12 CO NNECTOR
Manufacturer
Omron
Datasheet

Specifications of E2E2-X2B2-M1

Proximity Sensor Type
Inductive
Output Type
PNP
Proximity Sensor Sensing Distance
2mm
Proximity Sensor Sensing Distance Range
2 to 7mm
Proximity Sensor Switching Mode
NC
Mounting
Panel
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
10V
Operating Supply Voltage (typ)
12/15/18/24V
Operating Supply Voltage (max)
55V
Pin Count
4
Maximum Operating Temperature
+ 85 C
Operating Supply Voltage
10 V to 55 V
Sensing Distance
2 mm
Minimum Operating Temperature
- 40 C
Features
NC
Lead Free Status / Rohs Status
Compliant
J ACCESSORIES
J REPLACEMENT PARTS
Specifications
E2E2 3-Wire DC
Description
Mounting brackets
Silicone rubber covers for shielded sensors
Connector cordsets
Description
Mounting hardware including one pair of
metal nuts and one washer
Part number
Size
Type
Sensing distance
Supply voltage
(operating voltage
range)
Current consumption
Sensing object
Setting distance
Standard object
(mild steel)
Differential travel
Response frequency
Operation (with sensing
object approaching)
Control output
(switching capacity)
Circuit protection
Indicator
Ambient
temperature
Ambient
humidity
Temperature influence
Voltage influence
Residual voltage
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Operating
Operating
E2E2-X2Cj/Bj
M12
Shielded
2 mm (0.08 in)
±10%
12 to 24 VDC, ripple (p-p): 10% max., (10 to 55 VDC)
13 mA max.
Magnetic metals (refer to Engineering Data for non-magnetic metals)
0 to 1.6 mm
(0 to 0.06 in)
12 x 12 x
1 mm (0.47 x
0.47 x 0.04 in)
10% max. of sensing distance
1.5 kHz
B1/C1 models: Load ON
B2/C2 models: Load OFF
200 mA max., open collector
Reverse connection protection, surge absorber, load short-circuit protection
Operation indicator (red LED)
- -40°C to 85°C (- -40°F to 185°F) with no icing
35% to 95%
±15% max. of sensing distance at 23°C in temperature range of - -40°C to 85°C (- -40°F to 185°F)
±10% max. of sensing distance at 23°C in temperature range of - -25°C to 70°C (- -13°F to 158°F)
±1% max. of sensing distance in rated voltage range ±15%
2.0 V max. (under load current of 200 mA with cable length of 2 m)
50 MΩ min. (at 500 VDC) between current carry parts and case
1,000 VAC for 1 min between current carry parts and case
10 to 55 Hz, 1.5-mm double amplitude for 10 times each in X, Y, and Z axes
1,000 m/s
2
(approx. 100G) for 10 times each in X, Y, and Z axes
E2E2-X5MCj/Bj
Unshielded
5 mm (0.20 in)
±10%
0 to 4.0 mm
(0 to 0.16 in)
15 x 15 x 1 mm
(0.59 x 0.59 x
0.04 in)
0.4 kHz
Fits M12 size sensors
Fits M18 size sensors
Fits M30 size sensors
Fits M12 size sensors
Fits M18 size sensors
Fits M30 size sensors
See Y96E Connector Cordsets data sheet for details
Fits M12 size sensors
Fits M18 size sensors
Fits M30 size sensors
(This table continues on the next page.)
E2E2-X5Cj/Bj
M18
Shielded
5 mm (0.20 in)
±10%
0 to 4.0 mm
(0 to 0.16 in)
18 x 18 x
1 mm (0.71 x
0.71 x 0.04 in)
0.6 kHz
3
E2E2-X10MCj/Bj
Unshielded
10 mm (0.39 in)
±10%
0 to 8.0 mm
(0 to 0.31 in)
30 x 30 x 1 mm
(1.18 x 1.18 x
0.04 in)
0.2 kHz
Part number
Y92E-B12
Y92E-B18
Y92E-B30
Y92E-E12-2
Y92E-E18-2
Y92E-E30-2
Part number
M12-MHWS
M18-MHWS
M30-MHWS
E2E2-X10Cj/Bj
M30
Shielded
10 mm (0.39 in)
±10%
0 to 8.0 mm
(0 to 0.31 in)
30 x 30 x 1 mm
(1.18 x 1.18 x
0.04 in)
0.4 kHz
E2E2 3-Wire DC
E2E2-X18MCj/Bj
Unshielded
18 mm (0.71 in)
±10%
0 to 14.0 mm
(0 to 0.55 in)
54 x 54 x 1 mm
(2.13 x 2.13 x
0.04 in)
0.1 kHz

Related parts for E2E2-X2B2-M1