LQ050W1LA0A Sharp Electronics, LQ050W1LA0A Datasheet - Page 21

no-image

LQ050W1LA0A

Manufacturer Part Number
LQ050W1LA0A
Description
Manufacturer
Sharp Electronics
Datasheet

Specifications of LQ050W1LA0A

Lead Free Status / Rohs Status
Supplier Unconfirmed
13. Handling Precautions
a) Be sure to turn off the power supply when inserting or disconnecting the cable.
b) Be sure to design the cabinet so that the module can be installed without any extra stress such as warp or twist.
c) Since the touch panel surface is easily damaged, pay attention not to scratch it.
d) Wipe off water drop immediately. Long contact with water may cause discoloration or spots.
e) When the panel surface is soiled, wipe it with absorbent cotton or other soft cloth.
f) Since the panel is made of glass, it may break or crack if dropped or bumped on hard surface. Handle with care.
g) Since CMOS LSI is used in this module, take care of static electricity and injure the human earth when handling.
h) This module has its circuitry PCBs on the rear side and should be handled carefully in order not to be stressed.
i) Protect sheet is attached to the module surface to prevent it from being scratched. Peel the sheet off slowly just
j) Do not expose the LCD module to a direct sunlight, for a long period of time to protect the module from the ultra
k) Connect GND of module bezel to stabilize against EMI and external noise.
l) When handling LCD modules and assembling them into cabinets, please be noted that long-term storage in the
m) Adjusting volume have been set optimally before shipment, so do not change any adjusted value. If adjusted value
n) Disassembling the module can cause permanent damage and should be strictly avoided.
o) Please be careful since image retention may occur when a fixed pattern is displayed for a long time.
p) Please handle carefully not to charge excessive stress onto the back of the module. Excessive stress may cause
q) Don't give stress on the surface of the touch panel continuously. It causes unevenness (in such cases as the Newton’s
r) Liquid crystal contained in the panel may leak if the LCD is broken. Rinse it as soon as possible if it gets
Observe all other precautionary requirements in handling components.
before the use with strict attention to electrostatic charges. Ionized air shall be blown over during the action. Blow
off the 'dust' on the polarizer by using an ionized nitrogen gun, etc..
violet ray.
environment of oxidization or deoxidization gas and the use of such materials as reagent, solvent, adhesive, resin, etc.
which generate these gasses, may cause corrosion and discoloration of the LCD modules.
is changed, the specification may not be satisfied.
Do not peel off the tapes, and do not remove an internal connector.
The final form of the module is Figure 2.
inside your eye or mouth by mistake.
unrepairable damage to the module.
Ring) in the touch panel surface.
LD 20132B-18

Related parts for LQ050W1LA0A