pmE261
• General purpose ac/dc
• metallized paper
• IEC Publ. 166 Type 1
• High dU/dt capability.
• Excellent self-healing properties.
• Good resistance to ionisation due
For general use in DC and low frequency
pulse applications.
rated voltage u
rated voltage u
capacitance range, µf
capacitance tolerance
temperature range
climatic category
dissipation factor
insulation resistance
vibration
Bump
solderability IEC 60068-2-20 Solder globule method
Passive
flammability
humidity
Ensures long life even when
subjected to frequent overvoltages.
to impregnated dielectric.
tYpiCaL appLiCations
IEC 60068-2-6
Test Fc
IEC 60068-2-29 4000 bumps at 390 m/s
Test Eb
Test Ta
IEC 60695-2-2
IEC 60068-2-3
Test Ca
r
r
, vac
, vdc
PmE261 K
220
400
0.0082 - 1.0
—
± 10% code K
± 5% code J
AC application -40 to +70°C
DC application -40 to + 100°C
IEC 40/070/56
≤ 1.3 % at 1 kHz
C ≤ 0.33 µF
C > 0.33 µF
PME261 K measured at 100 VDC after 60 s, +23°C
PME261 E and J measured at 500 VDC after 60 s, +23°C
EnViRonmEntaL tEst data
3 directions at 2 hour each No visible damage
10 – 500 Hz at 0.75 mm or
98 m/s
+40°C and 90 – 95% R.H.
tECHniCaL data
2
• Approved according to SE-MIL-QPL.
• The capacitors meet the most
• The impregnated paper ensures
Multi-layer metallized paper. Encapsulated
and impregnated in self-extinguishing
material meeting the requirements of
UL 94V-0.
PmE261 E
300
630
0.001 - 0.15
± 20% code M
± 10% code K
—
12000 MΩ
4000 s
stringent IEC humidity class, 56 days.
excellent stability giving outstanding
reliability properties, especially in
applications having continuous
operation.
2
ConstRuCtion
No open or short circuit
No visible damage
No open or short circuit
Wetting time
for d ≤ 0.8 < 1 s
for d > 0.8 < 1.5 s
56 days
PmE261 J
500
1000
0.001 - 0.1
± 20% code M
± 10% code K
—
• RIFA
• RIFA article code
• Rated capacitance
• Rated voltage AC/DC
• MP, for metallized paper
• Climatic category according to
• Manufacturing code (year, month)
The article code for the standard part is
given in the article table.
For other options, see page 11.
IEC 60068-, appendix A
d = 0.6 for p = 10.2
l = standard: 30 +5/–0 mm
option 1:
option 2:
0.8 for p = 15.2 and 20.3
1.0 for p = 25.4
oRdERing inFoRmation
short leads, tolerance +0/-1 mm
(standard 6 mm, code R06)
Other lead lengths on request
30 mm insulated solid leads,
ordering code: replace R30
with R300PS in std P/N
p ± 0.5
maRKing
L
RoHS
Compliant
B
∅ d
41