HCPL-2400E Avago Technologies US Inc., HCPL-2400E Datasheet - Page 6

HCPL-2400E

Manufacturer Part Number
HCPL-2400E
Description
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of HCPL-2400E

Number Of Elements
1
Input Type
DC
Output Type
3-State
Forward Voltage
1.5V
Forward Current
10mA
Output Current
25mA
Isolation Voltage
3750Vrms
Package Type
PDIP
Operating Temp Range
0C to 70C
Power Dissipation
350mW
Propagation Delay Time
60ns
Pin Count
8
Mounting
Through Hole
Reverse Breakdown Voltage
2V
Operating Temperature Classification
Commercial
Lead Free Status / Rohs Status
Compliant
6
Insulation and Safety Related Specifications
Option 300 - surface mount classification is Class A in accordance with CECC 00802.
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics
(HCPL-2400 OPTION 060 ONLY)
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section IEC/EN/DIN EN 60747-5-2 for a
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must ben ensured by protective circuits in applica-
tion.
Parameter
Minimum External
Air Gap (External
Clearance)
Minimum External
Tracking (External
Creepage)
Minimum Internal
Plastic Gap
(Internal Clearance)
Tracking Resistance
(Comparative
Tracking Index)
Isolation Group
Description
Installation classification per DIN VDE 0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
Input to Output Test Voltage, Method a*
Highest Allowable Overvoltage*
(Transient Overvoltage, t
Safety Limiting Values
Insulation Resistance at T
detailed description.
V
V
for rated mains voltage ≤300 V rms
for rated mains voltage ≤450 V rms
Partial Discharge < 5 pC
t
(Maximum values allowed in the event of a failure,
also see Figure 12, Thermal Derating curve.)
m
IORM
IORM
Case Temperature
Input Current
Output Power
= 60 sec, Partial Discharge < 5 pC
x 1.875 = V
x 1.5 = V
PR
, Type and sample test,
PR
, 100% Production Test with t
ini
L(101)
L(102)
S
Symbol
, V
CTI
= 10 sec)
IO
= 500 V
Value
0.08
200
IIIa
7.1
7.4
m
= 1 sec,
Volts
Units
mm
mm
mm
Conditions
Measured from input terminals to output
terminals, shortest distance through air.
Measured from input terminals to output
terminals, shortest distance path along body.
Through insulation distance, conductor to
conductor, usually the direct distance between the
photoemitter and photodetector inside the
optocoupler cavity.
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
P
Symbol
I
S,OUTPUT
V
V
S,INPUT
V
V
IORM
R
IOTM
T
PR
PR
S
S
Characteristic
55/85/21
1181
6000
≥10
630
945
175
230
600
I-IV
I-III
2
9
V
V
V
V
Units
mW
mA
°C
Ω
peak
peak
peak
peak

Related parts for HCPL-2400E