LY2FAC220240 Omron, LY2FAC220240 Datasheet - Page 4

Electromechanical Relay DPDT 10A 220/240VAC 18.79KOhm Flange Mount

LY2FAC220240

Manufacturer Part Number
LY2FAC220240
Description
Electromechanical Relay DPDT 10A 220/240VAC 18.79KOhm Flange Mount
Manufacturer
Omron
Type
General Purpose Relayr
Datasheets

Specifications of LY2FAC220240

Contact Arrangement
DPDT
Ac Coil Voltage
220|240 V
Coil Current
4.2|4.6 mA
Mounting
Flange Mount
Relay Construction
Non-Latching
Contact Form
2 Form C
Coil Voltage Ac
220V/240V
Voltage Rating (vdc)
125V
Voltage Rating (vac)
250V
Dropout Volt (min)
72VACV
Coil Resistance
18.79kohm
Pick-up Voltage (max)
192VAC
Maximum Power Rating
240W/1.1KVA
Operate Time
25ms
Contact Current Rating
10A
Contact Material
Silver
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Unsealed
Product Height (mm)
42mm
Product Depth (mm)
22.5mm
Product Length (mm)
44mm
Operating Temp Range
-25C to 55C
Pin Count
8
Mounting Style
Flange
Termination Style
Quick Connect
Package / Case
Dust Cover
Lead Free Status / Rohs Status
Compliant
*Note: P level: λ 60 = 0.1 x 10
Note: 1. The values given above are initial values
Rated Load
Rated Carry
Current
Max. switching
voltage
Max. switching
current
Max. switching
power
Failure rate
(reference value)*
Contact resistance
Operate time
Release time
Max. operating frequency
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Endurance
Ambient temperature*
Ambient humidity
Weight
General Purpose Relay – LY
Contact Rating
Characteristics
Relay
2. The upper limit of 40°C for some Relays is because of the relationship between diode junction temperature and the element
Load
used.
Item
110 VAC 15 A
24 VDC 15 A
15 A
250 VAC
125 VDC
15 A
1,700 VA
360 W
100 mA, 5 VDC
Resistive load
(cosϕ = 1)
-6
/operation
1-pole
110 VAC 10 A
24 VDC 7 A
1,100 VA
170 W
Inductive load
50 mΩ max.
25 ms max.
25 ms max.
Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
100 MΩ min. (at 500 VDC)
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
2,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
Destruction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)
Destruction: 1,000 m/s
Malfunction: 200 m/s
Mechanical: AC: 50,000,000 operations min. (at 18,000 operations/hr)
DC: 1,00,000,000 operations min. (at 18,000 operations/hr)
Electrical: Single-, three-, and four-pole: 200,000 operations min.
(at 1,800 operations/hr under rated load)
Double-pole: 500,000 operations min. (at 1,800 operations/hr under rated load)
Operating:
Single- and double-pole standard, bifurcated-contact Relays: –25°C to 55°C (with no icing)
(–25°C to 70°C if carry current is 4 A or less)
All other Relays: –25°C to 40°C (with no icing)
(–25°C to 55°C if carry current is 4 A or less)
Operating: 5% to 85%
Single- and double-pole: approx. 40 g, three-pole: approx. 50 g, four-pole: approx. 70 g
All except Relays with bifurcated contacts
(cosϕ = 0.4,
L/R = 7 ms)
Single Contact
110 VAC 10 A
24 VDC 10 A
10 A
250 VAC
125 VDC
10 A
1,100 VA
240 W
100 mA, 5 VDC
Resistive load
2
(cosϕ = 1)
2
2-, 3- or 4-pole
110 VAC 7.5 A
24 VDC 5 A
825 VA
120 W
Inductive load
(cosϕ = 0.4,
L/R = 7 ms)
Relays with bifurcated contacts
110 VAC 5A
24 VDC 5 A
7 A
250 VAC
125 VDC
7 A
550 VA
120 W
100 mA, 5 VDC
Resistive load
(cosϕ = 1)
Bifurcated contacts
2-pole
110 VAC 4 A
24 VDC 4A
440 VA
100 W
Inductive load
(cosϕ = 0.4,
L/R = 7 ms)
445

Related parts for LY2FAC220240