B43501A9477M TDK Corporation, B43501A9477M Datasheet - Page 16

no-image

B43501A9477M

Manufacturer Part Number
B43501A9477M
Description
Cap Aluminum 470uF 400V 20% 35 X 45mm Snap-In 10mm 0.14 Ohm 2600mA 10000 hr Bulk
Manufacturer
TDK Corporation
Datasheet

Specifications of B43501A9477M

Mounting
Through Hole
Capacitance Value
470 uF
Voltage
400 Vdc
Tolerance
20 %
Lead Pitch For Radial
10 mm
Product Height
45 mm
Operating Temperature
-40 to 85 °C

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
B43501A9477M000
Manufacturer:
EPCOS
Quantity:
30 000
Part Number:
B43501A9477M007
Manufacturer:
EPCOS
Quantity:
30 000
Part Number:
B43501A9477M060
Manufacturer:
EPCOS
Quantity:
30 000
Part Number:
B43501A9477M067
Manufacturer:
EPCOS
Quantity:
30 000
Part Number:
B43501A9477M080
Manufacturer:
EPCOS
Quantity:
30 000
Cautions and warnings
Personal safety
The electrolytes used by EPCOS have not only been optimized with a view to the intended
application, but also with regard to health and environmental compatibility. They do not contain
any solvents that are detrimental to health, e.g. dimethyl formamide (DMF) or dimethyl acetamide
(DMAC).
Furthermore, part of the high-voltage electrolytes used by EPCOS are self-extinguishing. They
contain flame-retarding substances which will quickly extinguish any flame that may have been
ignited.
As far as possible, EPCOS does not use any dangerous chemicals or compounds to produce
operating electrolytes. However, in exceptional cases, such materials must be used in order to
achieve specific physical and electrical properties because no safe substitute materials are
currently known. However, the amount of dangerous materials used in our products has been
limited to an absolute minimum. Nevertheless, the following rules should be observed when
handling aluminum electrolytic capacitors:
Please read Cautions and warnings and
Important notes at the end of this document.
Any escaping electrolyte should not come into contact with eyes or skin.
If electrolyte does come into contact with the skin, wash the affected parts immediately with
running water. If the eyes are affected, rinse them for 10 minutes with plenty of water. If
symptoms persist, seek medical treatment.
Avoid breathing in electrolyte vapor or mists. Workplaces and other affected areas should be
well ventilated. Clothing that has been contaminated by electrolyte must be changed and
rinsed in water.
B43501
Long useful life
85 C
Page 16 of 21