EP2C35F672C6N Altera, EP2C35F672C6N Datasheet - Page 25

IC CYCLONE II FPGA 33K 672-FBGA

EP2C35F672C6N

Manufacturer Part Number
EP2C35F672C6N
Description
IC CYCLONE II FPGA 33K 672-FBGA
Manufacturer
Altera
Series
Cyclone® IIr
Datasheet

Specifications of EP2C35F672C6N

Number Of Logic Elements/cells
33216
Number Of Labs/clbs
2076
Total Ram Bits
483840
Number Of I /o
475
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
672-FBGA
Family Name
Cyclone® II
Number Of Logic Blocks/elements
33216
# I/os (max)
475
Frequency (max)
500MHz
Process Technology
90nm
Operating Supply Voltage (typ)
1.2V
Logic Cells
33216
Ram Bits
483840
Operating Supply Voltage (min)
1.15V
Operating Supply Voltage (max)
1.25V
Operating Temp Range
0C to 85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
672
Package Type
FBGA
For Use With
P0301 - DE2 CALL FOR ACADEMIC PRICING544-1733 - PCI KIT W/CYCLONE II EP2C35N649-1001 - KIT DEV CYCLONE II PCI EXPRESS
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Compliant
Other names
544-1694

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP2C35F672C6N
Manufacturer:
ALTERA
Quantity:
170
Part Number:
EP2C35F672C6N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP2C35F672C6N
Manufacturer:
ALTERA
0
Part Number:
EP2C35F672C6N
0
Altera Corporation
February 2007
Figure 2–9. Register Chain Interconnects
The C4 interconnects span four LABs, M4K blocks, or embedded
multipliers up or down from a source LAB. Every LAB has its own set of
C4 interconnects to drive either up or down.
interconnect connections from an LAB in a column. The C4 interconnects
can drive and be driven by all types of architecture blocks, including
PLLs, M4K memory blocks, embedded multiplier blocks, and column
and row IOEs. For LAB interconnection, a primary LAB or its LAB
neighbor (see
interconnects can drive each other to extend their range as well as drive
row interconnects for column-to-column connections.
Interconnect
Adjacent LE
Carry Chain
Routing to
Figure
Local
2–10) can drive a given C4 interconnect. C4
Local Interconnect
Routing Among LEs
in the LAB
Cyclone II Device Handbook, Volume 1
LE 10
LE 16
LE 1
LE 2
LE 3
LE 4
LE 5
LE 6
LE 7
LE 8
LE 9
LE 11
LE 12
LE13
LE 14
LE 15
Figure 2–10
Register Chain
Routing to Adjacent
LE's Register Input
Cyclone II Architecture
shows the C4
2–13