EP1S20F780C7N Altera, EP1S20F780C7N Datasheet - Page 42

IC STRATIX FPGA 20K LE 780-FBGA

EP1S20F780C7N

Manufacturer Part Number
EP1S20F780C7N
Description
IC STRATIX FPGA 20K LE 780-FBGA
Manufacturer
Altera
Series
Stratix®r
Datasheet

Specifications of EP1S20F780C7N

Number Of Logic Elements/cells
18460
Number Of Labs/clbs
1846
Total Ram Bits
1669248
Number Of I /o
586
Voltage - Supply
1.425 V ~ 1.575 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
780-FBGA
Family Name
Stratix
Number Of Logic Blocks/elements
18460
# I/os (max)
586
Frequency (max)
420.17MHz
Process Technology
0.13um (CMOS)
Operating Supply Voltage (typ)
1.5V
Logic Cells
18460
Ram Bits
1669248
Operating Supply Voltage (min)
1.425V
Operating Supply Voltage (max)
1.575V
Operating Temp Range
0C to 85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
780
Package Type
FC-FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Compliant
Other names
544-1855
EP1S20F780C7N

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP1S20F780C7N
Manufacturer:
ALTERA
Quantity:
3 000
Part Number:
EP1S20F780C7N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP1S20F780C7N
Manufacturer:
ALTERA
0
Part Number:
EP1S20F780C7N
Manufacturer:
ALTERA
Quantity:
200
Part Number:
EP1S20F780C7N
0
TriMatrix Memory
2–28
Stratix Device Handbook, Volume 1
M512 RAM blocks can have different clocks on its inputs and outputs.
The wren, datain, and write address registers are all clocked together
from one of the two clocks feeding the block. The read address, rden, and
output registers can be clocked by either of the two clocks driving the
block. This allows the RAM block to operate in read/write or
input/output clock modes. Only the output register can be bypassed. The
eight labclk signals or local interconnect can drive the inclock,
outclock, wren, rden, inclr, and outclr signals. Because of the
advanced interconnect between the LAB and M512 RAM blocks, LEs can
also control the wren and rden signals and the RAM clock, clock enable,
and asynchronous clear signals.
control signal generation logic.
The RAM blocks within Stratix devices have local interconnects to allow
LEs and interconnects to drive into RAM blocks. The M512 RAM block
local interconnect is driven by the R4, R8, C4, C8, and direct link
interconnects from adjacent LABs. The M512 RAM blocks can
communicate with LABs on either the left or right side through these row
interconnects or with LAB columns on the left or right side with the
column interconnects. Up to 10 direct link input connections to the M512
RAM block are possible from the left adjacent LABs and another
10 possible from the right adjacent LAB. M512 RAM outputs can also
connect to left and right LABs through 10 direct link interconnects. The
M512 RAM block has equal opportunity for access and performance to
and from LABs on either its left or right side.
RAM block to logic array interface.
Figure 2–15
shows the M512 RAM block
Figure 2–16
Altera Corporation
shows the M512
July 2005

Related parts for EP1S20F780C7N