EP3C16F256C8 Altera, EP3C16F256C8 Datasheet - Page 47

IC CYCLONE III FPGA 16K 256FBGA

EP3C16F256C8

Manufacturer Part Number
EP3C16F256C8
Description
IC CYCLONE III FPGA 16K 256FBGA
Manufacturer
Altera
Series
Cyclone® IIIr

Specifications of EP3C16F256C8

Number Of Logic Elements/cells
15408
Number Of Labs/clbs
963
Total Ram Bits
516096
Number Of I /o
168
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
256-FBGA
For Use With
544-2601 - KIT DEV CYCLONE III LS EP3CLS200P0037 - BOARD DEV/EDUCATION ALTERA DE0544-2411 - KIT DEV NIOS II CYCLONE III ED.
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Gates
-
Other names
544-2461

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP3C16F256C8
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP3C16F256C8
Manufacturer:
ALTERA
0
Part Number:
EP3C16F256C8
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP3C16F256C8N
Manufacturer:
ALTERA
Quantity:
816
Part Number:
EP3C16F256C8N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP3C16F256C8N
Manufacturer:
ALTERA
Quantity:
540
Part Number:
EP3C16F256C8N
Manufacturer:
XILINX
0
Part Number:
EP3C16F256C8N
Manufacturer:
ALTERA
Quantity:
200
Part Number:
EP3C16F256C8N
0
Chapter 2: Cyclone III LS Device Data Sheet
Electrical Characteristics
Table 2–3. Cyclone III LS Devices Recommended Operating Conditions
© December 2009
V
V
V
V
C CINT
C CIO
C CA
C CD_P LL
Symbol
(3)
(3),
(3)
(3)
(6)
Supply voltage for internal logic
Supply voltage for output buffers, 3.3-V
operation
Supply voltage for output buffers, 3.0-V
operation
Supply voltage for output buffers, 2.5-V
operation
Supply voltage for output buffers, 1.8-V
operation
Supply voltage for output buffers, 1.5-V
operation
Supply voltage for output buffers, 1.2-V
operation
Supply (analog) voltage for PLL regulator
Supply (digital) voltage for PLL
Altera Corporation
Figure 2–1
example, overshoot voltage is shown in red and is present on the input pin of the
Cyclone III LS device at over 4.1 V but below 4.2 V. From
of 4.1 V, the percentage of high time for the overshoot can be as high as 31.97% over a
10-year period. Percentage of high time is calculated as ([delta T]/T) × 100. This
10-year period assumes the device is always turned on with 100% I/O toggle rate and
50% duty cycle signal. For lower I/O toggle rates and situations in which the device is
in an idle state, lifetimes are increased.
Figure 2–1. Cyclone III LS Devices Overshoot Duration
Recommended Operating Conditions
This section lists the functional operation limits for AC and DC parameters for
Cyclone III LS devices.
The steady-state voltage and current values expected from Cyclone III LS devices are
provided in
Parameter
shows the methodology to determine the overshoot duration. In this
Table
2–3. All supplies must be strictly monotonic without plateaus.
4.2 V
4.1 V
3.3 V
ΔT
Conditions
(Note 1)
T
,
(2)
(Part 1 of 2)
3.135
2.375
1.425
2.375
1.15
2.85
1.71
1.14
1.15
Min
Table
Cyclone III Device Handbook, Volume 2
2–1, for an overshoot
Typ
1.2
3.3
3.0
2.5
1.8
1.5
1.2
2.5
1.2
3.465
2.625
1.575
2.625
Max
1.25
3.15
1.89
1.26
1.25
Unit
V
V
V
V
V
V
V
V
V
2–3

Related parts for EP3C16F256C8