EP1S80F1020C5N Altera, EP1S80F1020C5N Datasheet - Page 74

no-image

EP1S80F1020C5N

Manufacturer Part Number
EP1S80F1020C5N
Description
IC STRATIX FPGA 80K LE 1020-FBGA
Manufacturer
Altera
Series
Stratix®r
Datasheet

Specifications of EP1S80F1020C5N

Number Of Logic Elements/cells
79040
Number Of Labs/clbs
7904
Total Ram Bits
7427520
Number Of I /o
773
Voltage - Supply
1.425 V ~ 1.575 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
1020-FBGA
Family Name
Stratix
Number Of Logic Blocks/elements
79040
# I/os (max)
773
Frequency (max)
500MHz
Process Technology
0.13um (CMOS)
Operating Supply Voltage (typ)
1.5V
Logic Cells
79040
Ram Bits
7427520
Operating Supply Voltage (min)
1.425V
Operating Supply Voltage (max)
1.575V
Operating Temp Range
0C to 85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
1020
Package Type
FC-FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP1S80F1020C5N
Manufacturer:
ALTERA20
Quantity:
403
Part Number:
EP1S80F1020C5N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP1S80F1020C5N
Manufacturer:
XILINX
0
Part Number:
EP1S80F1020C5N
Manufacturer:
ALTERA
0
Digital Signal Processing Block
2–60
Stratix Device Handbook, Volume 1
Table 2–14
Multiplier
The multiplier supports 9 × 9-, 18 × 18-, or 36 × 36-bit multiplication. Each
DSP block supports eight possible 9 × 9-bit or smaller multipliers. There
are four multiplier blocks available for multipliers larger than 9 × 9 bits
but smaller than 18 × 18 bits. There is one multiplier block available for
multipliers larger than 18 × 18 bits but smaller than or equal to 36 × 36
bits. The ability to have several small multipliers is useful in applications
such as video processing. Large multipliers greater than 18 × 18 bits are
useful for applications such as the mantissa multiplication of a single-
precision floating-point number.
The multiplier operands can be signed or unsigned numbers, where the
result is signed if either input is signed as shown in
sign_a and sign_b signals provide dynamic control of each operand’s
representation: a logic 1 indicates the operand is a signed number, a logic
0 indicates the operand is an unsigned number. These sign signals affect
all multipliers and adders within a single DSP block and you can register
them to match the data path pipeline. The multipliers are full precision
(that is, 18 bits for the 18-bit multiply, 36-bits for the 36-bit multiply, and
so on) regardless of whether sign_a or sign_b set the operands as
signed or unsigned numbers.
Parallel input
Shift register input
Table 2–14. Input Register Modes
Table 2–15. Multiplier Signed Representation
Register Input Mode
Unsigned
Unsigned
Data A
Signed
Signed
shows the summary of input register modes for the DSP block.
9 × 9
v
v
Unsigned
Unsigned
Data B
Signed
Signed
18 × 18
v
v
Table
Altera Corporation
Unsigned
Signed
Signed
Signed
Result
2–15. The
36 × 36
v
July 2005

Related parts for EP1S80F1020C5N