XC5VLX30-1FF676C Xilinx Inc, XC5VLX30-1FF676C Datasheet - Page 340

IC FPGA VIRTEX-5 30K 676FBGA

XC5VLX30-1FF676C

Manufacturer Part Number
XC5VLX30-1FF676C
Description
IC FPGA VIRTEX-5 30K 676FBGA
Manufacturer
Xilinx Inc
Series
Virtex™-5 LXr

Specifications of XC5VLX30-1FF676C

Number Of Logic Elements/cells
30720
Number Of Labs/clbs
2400
Total Ram Bits
1179648
Number Of I /o
400
Voltage - Supply
0.95 V ~ 1.05 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
676-BBGA, FCBGA
Package
676FCBGA
Family Name
Virtex®-5
Device Logic Units
30720
Typical Operating Supply Voltage
1 V
Maximum Number Of User I/os
400
Ram Bits
1179648
For Use With
HW-AFX-FF676-500-G - BOARD DEV VIRTEX 5 FF676
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Gates
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XC5VLX30-1FF676C
Manufacturer:
Xilinx Inc
Quantity:
10 000
Part Number:
XC5VLX30-1FF676C
Manufacturer:
XILINX
0
Part Number:
XC5VLX30-1FF676C
Manufacturer:
XILINX
Quantity:
75
Part Number:
XC5VLX30-1FF676C
Manufacturer:
XLINX
Quantity:
20 000
Chapter 7: SelectIO Logic Resources
X-Ref Target - Figure 7-17
340
1 Clock Region
IDELAYCTRL
IDELAYCTRL Usage and Design Guidelines
This section describes using the IDELAYCTRL modules, design guidelines, and
recommended usage in Virtex-5 devices.
Instantiating IDELAYCTRL Without LOC Constraints
When instantiating IDELAYCTRL without LOC constraints, the user must instantiate only
one instance of IDELAYCTRL in the HDL design code. The implementation tools auto-
replicate IDELAYCTRL instances throughout the entire device. When IDELAYCTRL
instances are replicated to clock regions but not used, the extra instances are trimmed out
of the design automatically by the ISE software. The signals connected to the RST and
REFCLK input ports of the instantiated IDELAYCTRL instance are connected to the
corresponding input ports of the replicated IDELAYCTRL instances.
There are two special cases:
1.
Figure 7-17: Relative Locations of IDELAYCTRL Modules
When the RDY port is ignored, the RDY signals of all the replacement IDELAYCTRL
instances are left unconnected.
The VHDL and Verilog use models for instantiating an IDELAYCTRL primitive
without LOC constraints leaving the RDY output port unconnected are provided in
the Libraries Guide.
The resulting circuitry after instantiating the IDELAYCTRL components is illustrated
in
Column
Left I/O
Figure
7-18.
www.xilinx.com
Center I/O
Column
CMT
CMT
Configuration
Virtex-5 FPGA User Guide
UG190 (v5.3) May 17, 2010
Right I/O
Column
ug190_7_12_041206