2980652 Phoenix Contact, 2980652 Datasheet

no-image

2980652

Manufacturer Part Number
2980652
Description
DIN Rail Terminal Blocks PLC-OSC-5DC/300DC/1
Manufacturer
Phoenix Contact
Type
Wire to Wirer
Datasheets

Specifications of 2980652

Product
DIN Rail Terminal Blocks
Mounting Style
DIN Rail
Termination Style
Screw
Wire Gauge Max (awg)
14
Wire Gauge Min (awg)
26
Function
PLC
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
 
PLC-OSC- 5DC/300DC/ 1
Order No.: 2980652
The illustration shows the version PLC-OSC-24DC/300DC/1
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2980652
 
PLC relay, integrated optocoupler, with screw connection, for
mounting on DIN rail NS 35/7.5, input: 5 V DC, output: 12-300 V DC/1
A
PHOENIX CONTACT Inc., USA
http://www.phoenixcon.com
Commercial data
EAN
Pack
Customs tariff
Weight/Piece
Catalog page information
Technical data
Input data
Nominal input voltage U
Input voltage range in reference to U
Switching threshold "0" signal in reference to U
N
N
4046356051392
10 pcs.
85364900
0.03767 KG
Page 88 (IF-2007)
N
5 V DC
0.8 ... 1.2
≤ 0.4
Extract from the online
catalog
 
 
WEEE/RoHS-compliant since:
09/15/2006
http://
www.download.phoenixcontact.com
Please note that the data given
here has been taken from the
online catalog. For comprehensive
information and data, please refer
to the user documentation. The
General Terms and Conditions of
Use apply to Internet downloads.
Product notes
Jan 30, 2009
Page 1 / 4

Related parts for 2980652

2980652 Summary of contents

Page 1

... PLC-OSC- 5DC/300DC/ 1 Order No.: 2980652 The illustration shows the version PLC-OSC-24DC/300DC/1 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2980652   PLC relay, integrated optocoupler, with screw connection, for mounting on DIN rail NS 35/7.5, input DC, output: 12-300 V DC/1 A Commercial data EAN Pack Customs tariff Weight/Piece Catalog page information Technical data ...

Page 2

... Conductor cross section stranded min. Conductor cross section stranded max. Conductor cross section AWG/kcmil min. Conductor cross section AWG/kcmil max General data Length Width PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Order No.: 2980652 ≥ 0 0.8 ms 1.5 ms Yellow LED Polarity protection Surge protection ...

Page 3

... Inflammability class in acc. with UL 94 (housing) Pollution degree Surge voltage category Certificates / Approvals Certifications applied for: Drawings Diagram Circuit diagram PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Order No.: 2980652 86 mm -25 °C ... 60 °C -40 °C ... 85 °C Any In rows with zero spacing 100% operating factor V0 2 III UL / CUL / GL The illustration shows the derating curve for PLC- ...

Page 4

... PLC-OSC- 5DC/300DC/ 1 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2980652 Address PHOENIX CONTACT Inc., USA 586 Fulling Mill Road Middletown, PA 17057,USA Phone (800) 888-7388 Fax (717) 944-1625 http://www.phoenixcon.com © 2009 Phoenix Contact Technical modifications reserved; PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Order No.: 2980652 Page Jan 30, 2009 ...

Related keywords