3G3MV-C2037 Omron, 3G3MV-C2037 Datasheet - Page 6

no-image

3G3MV-C2037

Manufacturer Part Number
3G3MV-C2037
Description
Controllers 5HP 230V 3 PHASE 17.5A OUTPUT
Manufacturer
Omron
Type
AC Invertersr
Datasheet

Specifications of 3G3MV-C2037

Analog / Digital
Digital
Control Method
Sine wave PWM
Display Type
4-Digit Data
Voltage Rating
230 V
Mounting
Rail mount
Size
140 mm x 148 mm x 143 mm
Features
Programmable soft starts
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
6
\
Specifications
3G3MV-
MODEL
NEMA 4X MODEL V7CU-
Motor Output*
Allowable Frequency Fluctuation
Output Frequency Resolution
Allowable Voltage Fluctuation
Max. Output Frequency (Hz)
Frequency Reference Signal
Motor Overload Protection
Instantaneous Overcurrent
Frequency Control Range
Rated Output Current (A)
Power Charge Indication
Max. Output Voltage (V)
Momentary Power Loss
Inverter Capacity (kVA)
Storage Temperature*
(Temperature Change)
Max. Applicable
Stall Prevention Level
Cooling Method
Ambient Temperature
Wiring Distance
Cooling Fin Overheat
Rated Input Voltage
Frequency Accuracy
Standard Functions
Voltage Class
V/f Characteristics
Frequency Setting
Overload Capacity
Cooling Fan Fault
Accel/Decel Time
Control Method
Braking Torque
and Frequency
Undervoltage
Ground Fault
Overvoltage
Resolution
Single-phase NEMA-1
Three-phase NEMA-1
Multi-function
Multi-function
Overload
Humidity
Elevation
Vibration
Location
Single-phase IP-20
Three-phase IP-20
Output
1
Input
HP (kW)
3
*1: Based on a standard 4-pole motor for max. applicable motor output. Select the inverter model within the allowable motor rated current
*2: Shows deceleration torque for uncoupled motor decelerating from 60 Hz with the shortest possible deceleration time
*3: Temperature during shipping (for short period)
Sine wave PWM (V/f control/voltage vector control selectable)
0.1 to 400Hz
Digital reference: ±0.01% (-10 to +50˚C)
Analog reference: ±0.5% (25±10˚C)
Digital reference: 0.01 Hz (less than 100 Hz)/0.1 Hz (100 Hz or more)
Analog reference: (0:06/60 Hz) equivalent to 1/1000 of max. output frequency
0.01 Hz
150% rated output current for one minute
0 to 10 VDC (20 kΩ), 4 to 20 mA (250 Ω), 0 to 20 mA (250 Ω) pulse train input, frequency setting potentiometer (Selectable)
0.00 to 6000 sec. (accel/decel time are independently programmed 2 types)
Short-term average deceleration torque*
1.5 kW (2 HP): 50%; 2.2 kW (3 HP) or more: 20%
Continuous regenerative torque: Approx. 20% (150% with optional braking resistor, braking transistor built-in)
Possible to program any V/f pattern
Electronic thermal overload relay
Motor coasts to a stop at approx. 250% of inverter rated current
Motor coasts to a stop after 1 minute at 150% of inverter rated output current
Motor coasts to a stop if DC bus voltage exceed 410 V
Stops when DC bus voltage is approx. 200 V or less
(approx. 160 V or less for single-phase series)
Stops for 15ms or more. By setting inverter, operation can be continued if power is restored within approx. 0.5s
Protected by electronic circuit
Can be set individually during accel/decel, provided/not provided available during coast to a stop
Protected by electronic circuit (fan lock detection)
Protected by electronic circuit (overcurrent level)
ON until the DC bus voltage becomes 50V or less. RUN lamp stays ON or digital operator LED stays ON.
Cooling fan is provided for the following models: 200 V, 0.75 kW or larger inverters (3-phase)
200 V, 1.5 kW or larger inverters (single-phase) Others models are self-cooling
Open chassis IP20: -10 to +50˚C (14 to 122˚F)
Open chassis IP20 (Top-closed type) and enclosed wall mounted NEMA-1: -10 to +40˚C (14 to 105˚F) (not frozen)
95% RH or less (non-condensing)
-4 to 140˚F (-20 to +60˚C)
Indoor (free from corrosive gases or dust)
3280 ft (1000 m) or less
Up to 9.8 m/S2 (1 G) at less than 20 Hz, up to 2 m/S2 (0.2 G) at less than 20 to 50 Hz
328 ft (100 m) or less between Inverter and Motor
Seven of the following input signals are selectable: Forward/reverse run (3-wire sequence), fault reset, external fault (NO/NC
contact input), multi-step speed operation, Jog command, accel/decel time select, external baseblock (NO/NC contact input),
speed search command, UP/DOWN command, accel/decel hold command, LOCAL/REMOTE selection, communication/control
circuit terminal selection, emergency stop fault, emergency stop alarm, self test, PID control cancel, PID integral reset/hold
Following output signals are selectable (1 NO/NC contact output, 2 photo-coupler outputs): Fault, running, zero speed, at
frequency, frequency detection (output frequency ≤ or ≥ set value), during overtorque detection, during undervoltage detection,
minor error, during baseblock, operation mode, inverter run ready, during fault retry, during UV, during speed search, data output
through communication, PID feedback loss detection
Voltage vector control, full-range automatic torque boost, slip compensation, DC injection braking current/time at start/stop
frequency reference bias/gain, MEMOBUS communications (RS-485/422, max. 19.2 K bps), PID control, energy-saving control,
parameter copy, frequency reference with built-in potentiometer
C2001 C2002 C2004 C2007 C2015 C2022 C2037
A2001 A2002 A2004 A2007 A2015 A2022 A2037
CB001 CB002 CB004 CB007 CB015 CB022 CB037
AB001 AB002 AB004 AB007 AB015 AB022 AB037
(0.1)
0.13
0.3
0.8
Single-phase, 200 to 240 V (proportional to input voltage)
3-phase, 200 to 230 V (proportional to input voltage)
20P24 20P44 20P74 21P54 22P24 23P74
(0.2)
0.25
0.6
1.6
Single-phase, 200 to 240 V, 50/60Hz
3-phase, 200 to 230 V, 50/60Hz
230 VAC single- / three-phase
0.5/.75
(0.4)
1.1
3
(0.75)
1.9
1
5
(1.5)
3.0
2
8
2
; 0.1, 0.25 kW (0.13 HP, 0.25 HP): 150%; 0.55, 1.1 kW): (0.5 HP, 1 HP): 100%
(2.2)
4.2
11
3
(3.7)
17.5
6.7
400 Hz (Programmable)
5
-15% to +10%
C2055 C2075 C4004 C4007 C4015 C4022 C4037 C4055 C4075
A2055 A2075 A4004 A4007 A4015 A4022 A4037 A4055 A4075
25P54 27P54 40P44 40P74 41P54 42P24 43P74 45P54 47P54
(5.5)
7.5
9.5
25
±5%
(7.5)
13.0
10
33
Motor coasts to a stop if DC bus voltage exceeds 820 V
Stops when DC bus voltage is approx. 400 V or less
3-phase, 380 to 400 V (proportional to input voltage)
(0.4)
1.4
1.8
1
3-phase, 380 to 460 V, 50/60Hz
(0.75)
1.5/2
2.6
3.4
460 VAC three-phase
(1.5)
3.7
4.8
3
(2.2)
3.5
4.2
5.5
(3.7)
7.0
8.6
5
(5.5)
11.0
14.8
10
(7.5)
12.5
14.0
18