GRF303-12 TELEDYNE, GRF303-12 Datasheet
GRF303-12
Specifications of GRF303-12
Related parts for GRF303-12
GRF303-12 Summary of contents
Page 1
... The ultraminiature GRF300 and GRF303 relays are designed to provide a practical surface-mount solution with improved RF signal repeatability over the frequency range. GRF300 UNIFRAME and GRF303 relays feature a unique ground shield that isolates and shields each lead to ensure excellent contact- to-contact and pole-to-pole isolation. The GRF300/GRF303 ARMATURE ...
Page 2
... NRZ Eye/Mask mode measurements: rise time, fall time, eye ramp and bit rate 0 -10 -20 Notes: -30 • Data measured on GRF303 mounted on RF PCB • PCB made of Rogers 6002, 0.076” trace width • Connectors used on PCB are from Pasternack PE4004 -40 • Data includes the effect of PCB and connectors • Test Temperature: Ambient Room -50 • ...
Page 3
... SERIES GRF300 AND GRF303 TYPICAL RF CHARACTERISTICS (See RF Notes) Isolation Across Contacts (RF Note 4) 0 -10 -20 -30 -40 -50 -60 0 500 1000 1500 2000 2500 3000 3500 4000 Frequency (MHz) Insertion Loss (RF Note 6) 0 -0.2 -0.4 -0.6 -0 500 1000 1500 2000 2500 3000 3500 4000 Frequency (MHz) 1 ...
Page 4
... SERIES GRF300 AND GRF303 TYPICAL RF INSERTION LOSS REPEATABILITY CHARACTERISTICS (See RF Insertion Loss Repeatability Notes) REPEATABILITY CHARACTERISTICS GRF300 RELAYS Normally Closed 100% 80% 60% 40% 20 0.02 0.04 0.06 0.08 0.1 0.12 Repeatability (dB) REPEATABILITY CHARACTERISTICS GRF303 RELAYS Normally Closed 100% 80% 60% 40% 20 0.02 0.04 ...
Page 5
... TOLERANCES ON DIMENSIONS ARE ±.010 INCH (0.025 mm). 3. FOR OPTIMAL RF PERFORMANCE, 36° ±3° TYP SOLDER BOTTOM OF GROUND SHIELD TO PCB RF GROUND PLANE. DIA. (800) 284-7007 • www.teledynerelays.com GRF300-12 GRF303-12 12.0 390 850 9.0 SEE NOTE 3 .035 REF (.89) U.S. PATENT PENDING8 DIA. ...
Page 6
... Dimensions are in inches (mm). 4. Unless otherwise speci¿ ed, tolerance is ± .010 (.25). 5. Add the contact resistance show in the datasheet. 6. Add 0.01 oz. (0. the weight of the relay assembly shown in the datasheet. © 2008 Teledyne Relays Appendix A: Spacer Pads Height For use with the following: ...
Page 7
... Dim H MAX .014 [0.36] (REF) .370 [9.4] MIN +44 (0) 1236 453124 • www.teledyne-europe.com For use with the following: ER411T, J411T, ER412, ER412D ER412DD, J412, J412D, J412DD ER412T, J412T 712, 712D, 712TN ER431T, J431T, ER432, ER432D ER432DD, J432, J432D, J432DD ER432T, J432T ...
Page 8
... Centigrid® Relays: RF180, ER116C, 122C, ER136C Indicates ground pin position Indicates glass insulated lead position Indicates ground pin or lead position depending on relay type © 2008 Teledyne Relays "Z" POSITION "X" POSITION "Y" POSITION TO-5 Relays: ER411, ER431, RF311, RF331 " ...