CCT-58S34C-TD TELEDYNE, CCT-58S34C-TD Datasheet

no-image

CCT-58S34C-TD

Manufacturer Part Number
CCT-58S34C-TD
Description
Coaxial Switches DC-26.5GHz MULTI-THROW
Manufacturer
TELEDYNE
Datasheet

Specifications of CCT-58S34C-TD

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Specifications
RF Contacts:
Actuator
Switching Time:
Terminations:
Connectors:
Weight:
Temperature Range: -40
Shock:
Vibration:
Humidity:
Typical Contact Life:
RF Power Handling (Non-Terminated)
Specifications
VSWR (max)
Insertion Loss (min)
Isolation (max)
3000
800
400
200
DC-6 GHz 6-12 GHz 12-18 GHz 18-26.5 GHz
10
80
40
0.20 dB
70.0 dB
5 Million Cycles
1.25:1
Break before make
Voltage (VDC) 20
Current (mA)
15 msec max
50 Ohm 2 Watts CW max
SMA (f)
6 oz. max
MIL-STD-202 Method 213, Condition D (500G Non Operating)
MIL-STD-202 Method 214, Condition D (10G RMS Non Operating)
Moisture Seal Available
0.1
O
C to +65
0.40 dB
60.0 dB
1.40:1
O
C (Operating)
Frequency GHz
1.0
O
C
Multi-Throw Internal Terminations DC-26.5GHz
0.50 dB
60.0 dB
170 136 180
The CCT-58 Switch is an internally terminated, broadband, multi-throw, electromechanical
coaxial switch designed to switch a microwave signal from a common input to any of 3, 4, 5,
or 6 outputs. The characteristic impedance is 50 Ohms. Internal terminations provide an
impedance match for the unselected ports. The switches are small using the popular
connector spacing on a 1.062" dia. circle. Each position has an individual actuator mechanism
allowing random position selection. This also minimizes switching time.
1.50:1
12
4.0
15
Specifications subject to change without notice.
28
10
0.80 dB
50.0 dB
1.80:1
18
26.5
The CCT-58 comes with a normally open actuator. For the normally
open actuator, all ports are terminated in 50 Ohms, except the
common input port which is open when the switch is
de-energized.
Commercial
Insertion Loss Repeatability (1 Million Cycles):
DC to 6 GHz: 0.05 dB
DC to 20 GHz: 0.1 dB
0.4
0.0
15
25
0.01
0.01
Typical Performance
Frequency GHz
Frequency GHz
email: coax@teledyne.com
www.teledynecoax.com
Normally Open
Tel: (800) 351-7368
CCT-58
26.5
26.5
60
70
80
90
10/2007

Related parts for CCT-58S34C-TD

CCT-58S34C-TD Summary of contents

Page 1

... Each position has an individual actuator mechanism allowing random position selection. This also minimizes switching time. The CCT-58 comes with a normally open actuator. For the normally open actuator, all ports are terminated in 50 Ohms, except the ...

Page 2

... Analog H = 1.85 STD Model H = 2.50 TTL Model Part Numbering System for CCT-58 (Normally Open) Series Connectors Actuator Voltage Connector Actuator Voltage S: SMA Female 1: 28Vdc Normally Open 2: 15Vdc Normally Open 3: 12Vdc Normally Open For other options contact Factory Commercial Multi-Throw Internal Terminations DC-26.5GHz ...

Related keywords