LTIGK51-6S-WH-RC-NBL/125N/ON-O Carling Technologies, LTIGK51-6S-WH-RC-NBL/125N/ON-O Datasheet - Page 56

no-image

LTIGK51-6S-WH-RC-NBL/125N/ON-O

Manufacturer Part Number
LTIGK51-6S-WH-RC-NBL/125N/ON-O
Description
Rocker Switches & Paddle Switches ON-NONE-OFF DP LIGHTED
Manufacturer
Carling Technologies

Specifications of LTIGK51-6S-WH-RC-NBL/125N/ON-O

Contact Form
DP
Switch Function
ON - NONE - OFF
Contact Rating
15 Amps at 125 Volts
Termination Style
Tabs
Actuator
Curved/Smooth Face Gloss
Color
White
Mounting Style
Panel
Contact Plating
Gold
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
NOTES
Consult factory to verify horsepower rating for your particular circuit choice.
1
2
3
4
5
54
2 CIRCUIT
Terminal Connections as viewed
from bottom of switch:
8 terminal 10 terminal
8 - - 7
1 - - 4
2 - - 5
3 - - 6
Position:
SP
1
4
6
7
8
9
SPECIAL CIRCUITS
H*
G*
S
M*
R
E*
*Jumper between terminals 2 & 5 for circuits H, G, & M are specified in selection 4.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E
may be used for SP OFF-ON-ON circuit. Circuits H, M & E not available with ratings 5,8 &9.
3 RATING
1
4
5
8* 10A 250VAC, 15A 125VAC, 1/2 HP 125-250VAC, 12(2)A 250 VAC µ T85
9* 10A 250VAC, 15A 125VAC, 1/2 HP 125-250 VAC, 12(6)A 250 VAC T85
B 15A 24V
C 20A 18V
D 20A 12V
* Ratings 8 & 9 are UL, CSA, VDE, DEMKO, SEMKO, NEMKO, FIMKO & BEAB certified,
require terminations A or B for double pole circuits, & are not available with illumination cir-
cuits 4, 8, D, J, N, & T or with wire lead or solder lug terminations. Circuits 1, 4, A & D are
not available with rating 8. Rating 9 only available with circuits 1,4,A & D. Ratings 8 & 9
must specify lamp code 2 (250VAC neon).
Lamp above terminals 3 & 6 end of switch.
Positive (+) and negative (-) symbols apply to LED lamps only
Sealed Unsealed Lamps when Illuminated
S
C
H
Selections for Double Pole Switches Only:
M
Lock above terminals 1 & 4 end of switch.
W
8 term
1
A
J
3
C
5
E
Note: Codes J & K for circuits H, G & M. Ratings 8 & 9 require terminations A or B only.
5 ILLUMINATION & SWITCH SEALING
6 LOCK
1 SERIES
V
4 TERMINATION/BASE STYLE
Custom colors are available. Consult factory.
White imprinting is standard on black actuators; Black imprinting is standard on white, red
and gray actuators; Custom colors are available, consult factory.
Located over T1-4 end of switch.
Only available with 3 position circuits. Center OFF and special circuits only available with
center position lock function.
Additional ratings available. See page 57.
.4VA @ 28VDC Resistive
10A 250VAC 1/2 HP, 15A 125VAC 1/2 HP, No Listings
10A 250VAC 1/2 HP, 15A 125VAC 1/2 HP, UL Recognized, CSA Certified
1
Series
V
DP
A
D
J
K
L
N
Carling
Technologies
lock
10 term
2
B
K
4
D
6
F
0
3
Z
R
5
10 - - 9
8 - - 7
1 - - 4
2 - - 5
3 - - 6
(2 & 3, 5 & 6)
(2 & 3, 5 & 6)
2 & 3, 5 & 6
2 & 3, 5 & 6
2 & 3, 5 & 6
2
Circuit
1 D A S
2 & 3
5 & 6
(ON)
OFF
ON
ON
ON
ON
1
Termination
.250 TAB (QC) no barriers
.250 TAB (QC) with barriers
.250 TAB (QC) no barriers
Solder Lug no barriers
Solder Lug
Wire Leads no barriers
Wire Leads
None
# 2
# 2
# 2
3
Rating
Actuator Lens position
Up
Independent
Up
Connected Terminals
( ) - momentary
SP - single pole - uses terminals 1, 2 & 3.
DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
Terminals 7, 8, 9 & 10 for lamp circuit only.
4
Termination
2 & 3, 5 & 4
NONE
NONE
NONE
2 & 3
2 & 3
2 & 3
2 & 3
5 & 3
OFF
OFF
OFF
2
5
Illumination
Jumper
No
No
Yes T2 to 5
No
No
No
No
Lamp wired to
Terminals
3+
8+
3+
W 0 1
6
Lock
7-
7-
6-
1 & 2, 4 & 5
www.carlingtech.com
5 & 4
1 & 2
1 & 2
5 & 1
(ON)
(ON)
OFF
OFF
OFF
ON
ON
ON
3
V-Series Contura X Locking Sealed Rocker Switches
7
Lamp
8
Bracket
7 LAMP
Lamp above terminals 3 & 6 end of switch.
No lamp
Neon
Incandescent 4 3V
LED *
2VDC
6VDC
12VDC
24VDC
* Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma.
8 RAISED BRACKET COLOR
No Gasket
One Gasket
9 HARD SURFACE ACTUATOR
Contura X
10 LENS - above lamp #2 terminals 3,6
Z - No Lens
Clear
3
4
5
2
1
* All bottom lenses are molded of opaque material. Consult factory for other lens colors.
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
12 ACTUATOR, LENS OR BODY LEGENDS
13 LEGEND ORIENTATION
0
in selection 12)
1
2
3
4
11 ACTUATOR LOCK FUNCTION AND COLOR
Lock Color
Match Actuator
Black
White
Red
Safety Orange
00 - No Legend
21
25 O
For additional legend options & codes, see page 69 of this catalog
MC
13DMC-1
OFF
-
F
F
White
8
9
A
7
6
No legend
Orientation 1
Orientation 2
Orientation 3
Orientation 4
9
Actuator
1 P B
22
26
4F
1PM4F-1
0
1 125VAC 2 250VAC
Red
A
B
C
D
Black
1
4
Black
1
ON
O
N
Amber Green Red
D
E
F
C
B
Up
A
B
C
D
E
(used with codes 11-18
10
Lens
ORIENTATION 4
Actuator orientation above terminals:
23
27 O
Gray
2
45
18K45-2
Down
H
J
K
L
M
5 6V
Amber
L
M
N
P
White
2
5
J
K
L
H
G
O
3
1
, PANEL SEAL (external foam gasket)
11
Function
Red
3
1
ACTUATOR/LENS IN PANEL
P
R
S
N
M
24
28 I
Up & Down
R
S
T
V
W
6 12V
superbright superbright
Green
F
G
H
J
Gray
3
6
ORIENTATION OF
I
White
4
ORIENTATION 3
ORIENTATION 1
12
Legend
Blue
V
W
Y
U
T
00
2
3
7 18V
Red
R
S
T
V
Lens Style
Bar
One piece Square
Two piece Square*
(w/ clear top protective lens)
Two piece Square*
(w/ smoke top protective lens)
Two piece Square*
(w/ white top protective lens)
Center
1
2
3
4
5
3,6
-
4
1,4
8 24V
13
Legend
Orientation
ORIENTATION
0