20 INCH-G-P4V-MINI All Sensors Corporation, 20 INCH-G-P4V-MINI Datasheet

no-image

20 INCH-G-P4V-MINI

Manufacturer Part Number
20 INCH-G-P4V-MINI
Description
Board Mount Pressure Sensors 0-20in 4.5to5.5V Gauge
Manufacturer
All Sensors Corporation
Datasheet

Specifications of 20 INCH-G-P4V-MINI

Operating Pressure
0 in H2O to 20 in H2O
Pressure Type
Gauge
Output Type
Amplified
Mounting Style
Through Hole
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
4.5 V to 5.5 V
Package / Case
DIP-7
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Minia ture Amplified Low Pressure Sensors
Low Pressure (1” H
PRIME GRADE
General Description
The Miniature Amplified Output pressure sensors is based upon a proprietary technology to reduce all output
offset or common mode errors. This model provides a calibrated amplified output with superior output offset
characteristics. Output offset errors due to change in temperature, stability to warm-up, stability to long time
period, and position sensitivity are all significantly reduced when compared to conventional compensation
methods. In addition the sensor utilizes a silicon, micromachined, stress concentration enhanced structure to
provide a very linear output to measured pressure.
These calibrated and temperature compensated sensors give an accurate and stable output over a wide
temperature range. This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry
gases and the like.
The output of the device is ratiometric to the supply voltage and operation from any D.C. supply voltage between
4.5 and 5.5 volts.
All Sensors
2
O to 30 “ H
0.380
Pin 1 2 3 4
2
O) Sensors
(12.7)
0.50
Physical Dimensions
B-port
A-port
Equivalent Circuit
(15.7)
Typical
(2.54)
0.62
0.10
DS-0102 Rev A
Features
• 0 to 1” H
• Matched pressure port volumes
• Temperature Compensated ( -25 to 85° C)
• Calibrated Zero and Span
Applications
• Medical Instrumentation
• Environmental Controls
• HVAC
0.30
(7.6)
0.080 O.D.
(2.00)
2
O to 0 to 30” H
D1 version
or G verison
2
O Pressure Ranges
D2 version

Related parts for 20 INCH-G-P4V-MINI

20 INCH-G-P4V-MINI Summary of contents

Page 1

... PRIME GRADE General Description The Miniature Amplified Output pressure sensors is based upon a proprietary technology to reduce all output offset or common mode errors. This model provides a calibrated amplified output with superior output offset characteristics. Output offset errors due to change in temperature, stability to warm-up, stability to long time period, and position sensitivity are all significantly reduced when compared to conventional compensation methods ...

Page 2

... In H2O 5 INCH-G-P4V-MINI H2O 10 INCH-Dx-P4V-MINI ±10 In H2O 10 INCH-G-P4V-MINI H2O 20 INCH-Dx-P4V-MINI ±20 In H2O 20 INCH-G-P4V-MINI H2O 30 INCH-Dx-P4V-MINI ±30 In H2O 30 INCH-G-P4V-MINI H2O 60 INCH-Dx-P4V-MINI ±60 In H2O For differential pressure D1 is the package with two pressure ports the same side, D2 has two ports the opposite sides. ...

Page 3

... Span Shift (5°C-50°C), note 2 Performance Characteristics for 5 INCH-Dx-P4V-MINI Parameter, note 1 Operating Range, differential pressure Output Span, note 5 Offset Voltage @ zero differential pressure Offset Temperature Shift (-25°C-85°C), note 2 Offset Warm-up Shift, note 3 Offset Position Sensitivity (±1g) Offset Long Term Drift (one year) Linearity, hysteresis error, note 4 Span Shift (-25° ...

Page 4

... Minimum Nominal ±10.0 ±1.90 ±2.0 2.15 2.25 2 0.05 Minimum Nominal 10.0 3.90 0.15 0.25 2 0.05 Minia ture Amplified Low Pressure Sensors Maximum Units 5.0 mbar 4.0 4.10 volt 0.35 volt ±40 mvolt ±5 mvolt ±5 mvolt ±5 mvolt 0.25 %fs ± ...

Page 5

... Offset Warm-up Shift, note 3 Offset Position Sensitivity (±1g) Offset Long Term Drift (one year) Linearity, hysteresis error, note 4 Span Shift (-25°C-85°C), note 2 Performance Characteristics for 20 INCH-G-P4V-MINI Parameter, note 1 Operating Range, gage pressure Output Span, note 5 Offset Voltage @ zero pressure Offset Temperature Shift (-25°C-85°C), note 2 Offset Warm-up Shift, note 3 Offset Position Sensitivity (± ...

Page 6

... Offset Position Sensitivity (±1g) Offset Long Term Drift (one year) Linearity, hysteresis error, note 4 Span Shift (-25°C-85°C), note 2 Pressure Response: for any pressure applied the response time to get to 90% of pressure applied is typically less than 100 useconds. Specification Notes 1: A 5.0 ...