1MBAR-D-4V-MIL All Sensors Corporation, 1MBAR-D-4V-MIL Datasheet
![no-image](/images/no-image-200.jpg)
1MBAR-D-4V-MIL
Specifications of 1MBAR-D-4V-MIL
Related parts for 1MBAR-D-4V-MIL
1MBAR-D-4V-MIL Summary of contents
Page 1
... In H2O H2O Pressure Sensors General Description The Amplified line of low pressure sensors is based upon a proprietary technology to reduce all output offset or common mode errors. This model provides a ratiometric 4-volt output with superior output offset characteristics. Output offset errors due to change in temperature, stability to warm-up, stability to long time period, and position sensitivity are all significantly reduced when compared to conventional compensation methods ...
Page 2
... Minimum Nominal ±1.80 2.00 2 NOTE Amplified Low Pressure Sensors Military Grade -40 to 125° C -40 to 125° C -40 to 125° 95% RH (non condensing) Proof Pressure Burst Pressure 100 In H2O 200 In H2O 100 In H2O 200 In H2O 300 In H2O 200 In H2O 200 In H2O ...
Page 3
... Span Shift (-40°C-125°C), 2 NOTE Performance Characteristics for 5 INCH-D-4V-MIL Parameter, note 1 Operating Range, differential pressure Output Span, note 5 Offset Voltage @ zero differential pressure Offset Temperature Shift (-40°C-125°C), Offset Warm-up Shift, 3 NOTE Offset Position Sensitivity (±1g) Offset Long Term Drift (one year) ...
Page 4
... NOTE Minimum Nominal 3.90 0.15 2 NOTE Minimum Nominal ±1.90 2.15 2 NOTE Minimum Nominal 3.90 0.15 2 NOTE Amplified Low Pressure Sensors Military Grade Maximum Units 5.0 “H2O 4.0 4.10 volt 0.25 0.35 volt ±40 mvolt ±5 mvolt ±5 mvolt ±5 mvolt 0.05 ...
Page 5
... Span Shift (-40°C-125°C), 2 NOTE Performance Characteristics for 30 INCH-D-4V-MIL Parameter, note 1 Operating Range, differential pressure Output Span, note 5 Offset Voltage @ zero differential pressure Offset Temperature Shift (-40°C-125°C), Offset Warm-up Shift, 3 NOTE Offset Position Sensitivity (±1g) Offset Long Term Drift (one year) ...
Page 6
... Offset Long Term Drift (one year) Linearity, hysteresis error, 4 NOTE Span Shift (-40°C-125°C), 2 NOTE Equivalent Circuit Pressure Response: for any pressure applied the response time to get to 90% of pressure applied is typically less than 500 useconds. Specification Notes 1: A 5.0 NOTE LL PARAMETERS ARE MEASURED AT VOLT EXCITATION P ...