TL-W3MB1-R 2M Omron, TL-W3MB1-R 2M Datasheet
TL-W3MB1-R 2M
Specifications of TL-W3MB1-R 2M
Related parts for TL-W3MB1-R 2M
TL-W3MB1-R 2M Summary of contents
Page 1
... All models provided with an operation indicator. Mounting possible from either the front or rear of the housing. Protected to endure water and oil splashes (conforms to IEC IP67). DC 2-wire models (TL-W5MD1/-W5MD2) provide easy wiring. Ordering Information DC 2-wire Sensing head Sensing distance Non-shielded ...
Page 2
... Distance between any two adjacent standard sensing objects: Twice as wide as the width of the standard sensing object. 2 TL-W5MD Load ON Load OFF Operation indicator (red LED), operation set indicator (green LED) Operation indicator (red LED) 2 (approx. 50G) for 3 times each and Z directions TL-W/WM ...
Page 3
... V max. (with 2.0 V max. (with 50 mA load current 200 mA load current and 2-m cable) and 2-m cable) 2 (approx. 50G) for 3 times each and Z directions Approx Approx ADC (Al die-cast) TL-W/WM TL-W5 TL-W20M VDC ( VDC VDC VDC (iron mm 15% of sensing distance 40 Hz ...
Page 4
... Sensing object: X (mm) Iron Sensing object Sensing head Y (mm) 4 TL-W5M Y Sensing object: X Sensing Iron object 1 mm Sensing head Y (mm) TL-W20M Sensing distance X (mm) Sensing object: Iron Sensing head TL-W/WM Sensing object: Iron Sensing object X Sensing head Y (mm) Y Sensing object X Y (mm) ...
Page 5
... Brass Aluminum Object diameter d (mm) TL-W3M Iron Stainless steel (SUS304) Brass Aluminum Copper Object diameter d (mm) TL-W20M Iron d Sensing object X Stainless steel (SUS304) Copper Aluminum Object diameter d (mm) TL-W/WM TL-W5M Object: Iron Operate Release d Sensing object X Object diameter d (mm) 5 ...
Page 6
... V Note: Maximum load current: 100 mA TL-W1R5MB1 TL-W3MB TL-W5MB1 Brown Black Main circuit 100 Blue 6 Brown Load Blue Brown Blue Load TL-W5E TL-W20ME Brown +V 100 Load Black 4.7 k (see note 1) Main circuit Output 2.2 (see note 2) Blue 0 V Note: 1. Maximum load current: 200 mA 2 ...
Page 7
... Stable Proximity zone Non-sensing zone sensing zone Sensor Sensing object Rated sensing Lit distance Not lit Lit Not lit ON OFF DC 3-wire TL-W1R5M 1 TL-W3M TL-W5M Sensing Yes object No ON Output transistor OFF (load) Lit Operation indicator Not lit TL-W5F Sensing Yes object ...
Page 8
... Standard length (oil-tight) Operation indicator TL-W5M : Round vinyl-insulated cable (4 dia., 0.12 dia. x 18, 3 cores) 30.5 Standard length (oil-tight) 8.5 TL-W5MD : Round vinyl-insulated cable (4 dia., 0.12 dia. x 27, 2 cores) 18 4.5 Standard length (oil-tight) 12 0.1 3.5 Two, 3 mounting holes 12.5 7 ...
Page 9
... Standard cable length Approx Operation indicator Sensing surface 30 0 0.1 5 Two, 5.5 dia. mounting holes TL-W/WM Mounting Holes 15 0.2 Two, 4.5 dia. holes 6 1.5 Round vinyl-insulated cable (6 dia., 0.12 dia. x 45, 3 cores) Standard length ...
Page 10
... TL-W/WM Precautions Effects of Surrounding Metals Provide a minimum distance as shown in the table below between the TL-W and the surrounding metals to prevent the TL-W from be- ing induced by the metals and malfunctioning or being affected by the heat radiated by the metals. Model m TL-W1R5Mj1 TL-W3M TL-W5MD 5 mm ...
Page 11
... To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. E221-E1-2 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Systems Components Division H.Q. 28th Fl., Crystal Tower Bldg. 1-2-27, Shiromi, Chuo-ku, Osaka 540 Japan Phone: 06-949-6012 Fax: 06-949-6021 11 12 TL-W/WM Printed in Japan 0196-1.5M (1291) a ...