HEL-717-T-0-18-00 Honeywell, HEL-717-T-0-18-00 Datasheet - Page 5

Industrial Temperature Sensors 100 Ohm 0.2% resistance

HEL-717-T-0-18-00

Manufacturer Part Number
HEL-717-T-0-18-00
Description
Industrial Temperature Sensors 100 Ohm 0.2% resistance
Manufacturer
Honeywell
Datasheet

Specifications of HEL-717-T-0-18-00

Temperature Range
- 75 C to + 540 C
Product
Temperature Sensors
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Temperature Sensors
Platinum RTDs
FUNCTIONAL BEHAVIOR
R
RT
R
T
A
CONSTANTS
Both
RESISTANCE VS TEMPERATURE CURVE
SPECIFICATIONS
88
Alpha,
Delta, ( C)
Beta,
A ( C
B ( C
C ( C
Sensor Type
Temperature Range
Temperature Accuracy
Base Resistance and
Interchangeability, R
Linearity
Time Constant
Operating Current
Stability
Self Heating
Insulation Resistance
Construction
Lead Material
T
0
Temperature in C
R
Resistance ( ) at 0 C
Resistance ( ) at temperature T ( C)
-1
-2
-4
0
)
)
)
(1 AT BT
( C)
100
Honeywell
( C
0 and C
-1
)
2
B
100CT
0 for T 0 C
0
Sensing and Control 1-800-537-6945 USA
3.81 10
0.00375
1.605
0.16
0.000029
6.02 10
6.0 10
100
R
3
0
2
CT
0.009
-3
-12
-7
Thin film platinum RTD;
R
R
TFE Teflon:
Fiberglass:
1000
1000
2 mA maximum for self heating errors of
Alumina case; Epoxy potting (Teflon leads); Ceramic potting (fiberglass leads)
Nickel coated stranded copper, Teflon or Fiberglass insulated
4
)
0
0
0.5 C or 0.8% of temperature, C (R
0.3 C or 0.6% of temperature, C (R
0.1% of full scale for temperatures spanning
2.0% of full scale for temperatures spanning
0.5 sec. 0.85 inch O.D. in water at 3 ft/sec;
0.25 C/year; 0.05 C per 5 years in occupied environments
15 mW/ C for 0.85 O.D. typical
50 M at 50 VDC at 25 C
1000
100
2
1
C
0.003850
1.4999
0.10863
3.908 10
T 0
0.000010
5.775 10
4.183 10
@ 0 C; alpha
( 0.2%) @ 0 C
( 0.1%) @ 0 C (optional)
@ 0 C; alpha
75 to
200 to
100
0.007
4
-3
-7
-12
540 C ( 100 to
260 C ( 320 to
0.00385 / / C
0.00375 / / C
1-815-235-6847 International 1-800-737-3360 Canada
ACCURACY VS TEMPERATURE
*1000 RTD. Divide
NIST CALIBRATION
NIST traceable calibration provides resistance readings at 1, 2 or
3 standard temperature points to yield a resistance versus tem-
perature curve with 10x better accuracy.
Temperature
Calibration
Tolerance
0
0
T ( C)
-200
-100
( C)
100
200
300
400
500
600
100
200
300
400
500
600
200
100
0
0.2% trim), whichever is greater
0.1% trim), whichever is greater (optional)
1000 F)
0
1 C; 1 mA recommended
500 F)
1.0 sec, 0.85 inch O.D. in still water
40 to
75 to
by 10 for 100 RTD.
Standard
11.0
12.5
15.1
1 Point
( )
6.8
2.9
2.0
2.9
5.6
8.2
0.9
0.5
0.03
0.4
0.8
1.2
1.6
2.0
2.6
T ( C)
R*
125 C
540 C
0.2%
( C)
1.6
0.8
0.5
0.8
1.6
2.4
3.2
4.0
4.8
T
2 Point
0.27
0.03
0.11
0.2
0.33
0.5
0.8
1.2
T ( C)
HEL-700 Series
Optional
10.4
( )
5.1
2.4
1.0
2.2
4.3
6.2
8.3
9.6
R*
3 Point
0.15
0.03
0.07
0.08
6.2
8.3
9.6
10.4
T ( C)
0.1%
( C)
1.2
0.6
0.3
0.6
1.2
1.8
2.5
3.0
3.3
T

Related parts for HEL-717-T-0-18-00