MAX1989MUE Maxim Integrated Products, MAX1989MUE Datasheet - Page 11

no-image

MAX1989MUE

Manufacturer Part Number
MAX1989MUE
Description
Board Mount Temperature Sensors
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX1989MUE

Full Temp Accuracy
+/- 3.5 C, +/- 5 C
Package / Case
TSSOP-16
Digital Output - Bus Interface
Serial (2-Wire)
Digital Output - Number Of Bits
7 bit + Sign
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 55 C
Output Type
Digital
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAX1989MUE
Manufacturer:
MAXIM
Quantity:
6
Part Number:
MAX1989MUE
Manufacturer:
SIPEX
Quantity:
1
Company:
Part Number:
MAX1989MUE
Quantity:
105
There is a continuity fault detector at DXP_ that detects
whether the remote diode has an open-circuit condi-
tion. At the beginning of each conversion, the diode
fault is checked, and the status byte is updated. This
fault detector is a simple voltage detector; if DXP_ rises
above V
fault is detected. Note that the diode fault is not
checked until a conversion is initiated, so immediately
after power-on reset, the status byte indicates no fault
is present, even if the diode path is broken.
If any remote channel is shorted (DXP_ to DXN_ or
DXP_ to GND), the ADC reads 0000 0000 so as not to
trip either the T
tings. In applications that are never subjected to 0°C in
normal operation, a 0000 0000 result can be checked
to indicate a fault condition in which DXP_ is acciden-
tally short circuited. Similarly, if DXP_ is short circuited
to V
channels, and the device alarms.
The ALERT interrupt output signal is latched and can
only be cleared by reading the alert response address.
Table 2. Data Format (Two’s Complement)
+130.00
+127.00
+126.50
+126.00
+25.25
TEMP
-25.00
-25.50
-54.75
-55.00
-65.00
-70.00
+0.50
+0.25
+0.00
-0.25
-0.50
-0.75
-1.00
(°C)
CC
, the ADC reads +127°C for all remote and local
CC
- 1V (typ) due to the diode current source, a
ROUNDED
TEMP
HIGH
+127
+127
+127
+126
(°C)
+25
-25
-25
-55
-55
-65
-65
+1
+0
+0
+0
+0
-1
-1
______________________________________________________________________________________
or T
LOW
DIGITAL OUTPUT DATA BITS
SIGN
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
alarms at their POR set-
Diode Fault Alarm
A A L L E E R R T T Interrupts
MSB
111
111
111
111
001
000
000
000
000
000
111
111
110
110
100
100
011
011
1111
1111
1111
1110
1001
0000
0000
0000
0000
0000
1111
1111
0111
0110
1001
1001
1111
1111
LSB
Multichannel Remote/Local
Interrupts are generated in response to T
comparisons and when a remote diode is disconnected
(for continuity fault detection). The interrupt does not halt
automatic conversions; new temperature data continues
to be available over the SMBus interface after ALERT is
asserted. The interrupt output pin is open drain so that
devices can share a common interrupt line. The interrupt
rate can never exceed the conversion rate.
The interface responds to the SMBus alert response
address, an interrupt pointer return-address feature
(see Alert Response Address section). Prior to taking
corrective action, always check to ensure that an inter-
rupt is valid by reading the current temperature.
The SMBus alert response interrupt pointer provides
quick fault identification for simple slave devices that
lack the complex, expensive logic needed to be a bus
master. Upon receiving an ALERT interrupt signal, the
host master can broadcast a receive byte transmission
to the alert response slave address (0001 100). Then
any slave device that generated an interrupt attempts
to identify itself by putting its own address on the bus
(Table 3).
The alert response can activate several different slave
devices simultaneously, similar to the I
more than one slave attempts to respond, bus arbitra-
tion rules apply, and the device with the lower address
code wins. The losing device does not generate an
acknowledge and continues to hold the ALERT line low
until serviced (implies that the host interrupt input is
Table 3. Read Format for Alert Response
Address (0001100)
(MSB)
(LSB)
Temperature Sensors
BIT
7
6
5
4
3
2
1
0
NAME
ADD7
ADD6
ADD5
ADD4
ADD3
ADD2
ADD1
1
Provide the current
MAX1668/MAX1805/MAX1989
slave address that was latched at
POR (Table 8)
Logic 1
Alert Response Address
FUNCTION
2
C general call. If
HIGH
and T
LOW
11

Related parts for MAX1989MUE