EMC6D103S-CZC SMSC, EMC6D103S-CZC Datasheet - Page 25

no-image

EMC6D103S-CZC

Manufacturer Part Number
EMC6D103S-CZC
Description
Industrial Temperature Sensors Auto Fan Contrllr Up to 4 Fans
Manufacturer
SMSC
Datasheet

Specifications of EMC6D103S-CZC

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
SMSC EMC6D103
6.4
Interrupt Status Registers
If auto fan option is selected, the hardware will adjust the operation of the fans accordingly. See the
section titled
The results of each sampling and conversion can be found in the Reading Registers and are available
at any time, however, they are only updated once per conversion cycle.
The Hardware Monitor Block contains two interrupt status registers:
Register 1 on page 61
voltage and fan violation of limit error conditions and diode fault conditions that the Hardware Monitor
Block monitors.
When an error occurs during the conversion cycle, its corresponding bit is set in its respective interrupt
status register. The bit remains set until the register is read by software, at which time the bit will be
cleared to ‘0’ if the associated error event no longer violates the limit conditions or if the diode fault
condition no longer exists. Reading the register will not cause a bit to be cleared if the source of the
status bit remains active.
These registers are read only – a write to these registers have no effect. These registers default to
0x00 on VCC POR and Initialization.
See the description of the Interrupt Status registers in
Each interrupt status bit has a corresponding bit located in an interrupt enable register, which may be
used to enable/disable the individual event from setting the status bit. See the following figure for the
status and enable bits used to control the interrupt bits and INT# pin.
Auto Fan Control Operating Mode on page
and
on page
DATASHEET
62. These registers are used to reflect the state of all temperature,
25
Chapter 8, "Register Set," on page
34.
Register 41h: Interrupt Status
Revision 0.3 (03-01-07)
49.