EMC6D103-CZC SMSC, EMC6D103-CZC Datasheet - Page 66

no-image

EMC6D103-CZC

Manufacturer Part Number
EMC6D103-CZC
Description
Industrial Temperature Sensors Auto Fan Contrllr Up to 4 Fans
Manufacturer
SMSC
Datasheet

Specifications of EMC6D103-CZC

Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EMC6D103-CZC
Manufacturer:
SMSC
Quantity:
20 000
Revision 0.3 (03-01-07)
8.2.15
8.2.16
Register
Address
Register
Address
54h
55h
56h
57h
58h
59h
5Ah
5Bh
5Ch
5Dh
5Eh
Read/
Read/
Write
Write
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Registers 54-5Bh: Fan Tachometer Low Limit
Setting the Lock bit has no effect on these registers.
The Fan Tachometer Low Limit registers indicate the tachometer reading under which the
corresponding bit will be set in the Interrupt Status Register 2 register. In Auto Fan Control mode, the
fan can run at high speeds (100% duty cycle), so care should be taken in software to ensure that the
limit is low enough not to cause sporadic alerts. Note that an interrupt status event will be generated
when the tachometer reading is greater than the minimum tachometer limit.
The fan tachometer will not cause a bit to be set in the interrupt status register if the current value in
the associated Current PWM Duty registers is 00h or if the PWM is disabled via the PWM
Configuration Register.
Interrupts will never be generated for a fan if its tachometer minimum is set to FFFFh.
Registers 5C-5Eh: PWM Configuration
These registers become read only when the Lock bit is set. Any further attempts to write to these
registers shall have no effect.
Bits [7:5] Zone/Mode
Bits [7:5] of the PWM Configuration registers associate each PWM with a temperature sensor.
When in Auto Fan Mode, the PWM will be assigned to a zone, and its PWM duty cycle will be
adjusted according to the temperature of that zone. If ‘Hottest’ option is selected (101 or 110), the
PWM will be controlled by the hottest of zones 2 and 3, or of zones 1, 2, and 3. If one of these
options is selected, the PWM is controlled by the limits and parameters for the zone that requires
the highest PWM duty cycle, as computed by the auto fan algorithm.
PWM 1 Configuration
PWM 2 Configuration
PWM 3 Configuration
Register Name
Tach1 Minimum MSB
Tach2 Minimum MSB
Tach3 Minimum MSB
Tach4 Minimum MSB
Tach1 Minimum LSB
Tach2 Minimum LSB
Tach3 Minimum LSB
Tach4 Minimum LSB
Table 8.24 Registers 54-5Bh: Fan Tachometer Low Limit
Register Name
Table 8.25 Registers 5C-5Eh: PWM Configuration
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
(MSb)
ZON2
ZON2
ZON2
Bit 7
DATASHEET
(MSb)
Bit 7
15
15
15
15
7
7
7
7
ZON1
ZON1
ZON1
Bit 6
66
Bit 6
14
14
14
14
6
6
6
6
ZON0
ZON0
ZON0
Bit 5
Bit 5
13
13
13
13
5
5
5
5
Bit 4
INV
INV
INV
Bit 4
12
12
12
12
4
4
4
4
Bit 3
RES
RES
RES
Bit 3
11
11
11
11
3
3
3
3
SPIN2
SPIN2
SPIN2
Bit 2
Bit 2
10
10
10
10
2
2
2
2
SPIN1
SPIN1
SPIN1
Bit 1
Bit 1
1
9
1
9
1
9
1
9
SMSC EMC6D103
SPIN0
SPIN0
SPIN0
(LSb)
(LSb)
Bit 0
Bit 0
0
8
0
8
0
8
0
8
Datasheet
Default
Default
Value
Value
FFh
FFh
FFh
FFh
FFh
FFh
FFh
FFh
62h