PB-600-12 Mean Well, PB-600-12 Datasheet

no-image

PB-600-12

Manufacturer Part Number
PB-600-12
Description
Battery Chargers Float Charge 13.6V 135-400AH RECOM BAT
Manufacturer
Mean Well
Datasheet

Specifications of PB-600-12

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
FUNCTION
ENVIRONMENT
SAFETY &
EMC
(Note 2)
OTHERS
NOTE
BOOST CHARGE VOLTAGE
FLOAT CHARGE VOLTAGE
RECOMMENDED BATTERY
CAPACITY(AMP HOURS)
BATTERY TYPE
OUTPUT CURRENT
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
POWER FACTOR (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER VOLTAGE
OVER TEMPERATURE
REMOTE CONTROL
LEAKAGE CURRENT FROM BATTERY (Typ.)
FAST CHARGE
CHARGING OK
OUTPUT OK
TEMPERATURE SENSE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
600W Single Output Battery Charger
(Note 3)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
Open: Normal work
1mA
2 / 3 / 8 stage selectable
Relay contact (RY15)
Relay contact (RY13)
By NTC
14.4V
13.8V
135 ~ 400AH
Open & Sealed Lead Acid
40A
90 ~ 264VAC
47 ~ 63Hz
6.8A/115VAC
25A/115VAC
<3.5mA / 240VAC
16 ~ 18V
Protection type : Shut down o/p voltage, re-power on to recover
-20 ~ +60 (refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL1012, TUV EN60335-1, EN60335-2-29 (except for 48V), EN60950-1(48V only) approved
I/P-O/P:3KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22)
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024; light industry level, criteria A
135.6Khrs min.
230*158*67mm(L*W*H)
2.2Kg; 6pcs/14.2Kg/1.76CUFT
PB-600-12
86%
0.95/230VAC
0.05%/
(0 ~ 50 )
3.4A/230VAC
I/P-FG:1.8KVAC
127 ~ 370VDC
0.98/115VAC at full load
50A/230VAC
MIL-HDBK-217F (25 )
Short: Stop Charging
O/P-FG:0.5KVAC
27.6V
70 ~ 210AH
21A
28.8V
32 ~ 35V
PB-600-24
87%
PB-600
55.2V
35 ~ 105AH
10.5A
57.6V
64.5 ~ 69.5V
PB-600-48
89%
File Name:PB-600-SPEC 2011-04-20
..
series

Related parts for PB-600-12

PB-600-12 Summary of contents

Page 1

... Single Output Battery Charger SPECIFICATION MODEL PB-600-12 BOOST CHARGE VOLTAGE 14.4V FLOAT CHARGE VOLTAGE 13.8V RECOMMENDED BATTERY OUTPUT 135 ~ 400AH CAPACITY(AMP HOURS) (Note 3) BATTERY TYPE Open & Sealed Lead Acid OUTPUT CURRENT 40A VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 86% POWER FACTOR (Typ ...

Page 2

... Start V boost Charge Voltage 100% 10% Charge Current Green Color of LED PB-600 Case No.805C Unit:mm 42.5 ON/OFF SWITCH Air flow direction Terminal or equivalent Constant Current Constant Voltage Float stage 1 stage 2 stage 3 Orange Green File Name:PB-600-SPEC 2011-04-20 series INLET V boost V float 100% 10% ...

Page 3

... Green PWM fosc : 60KHz RECTIFIER & FILTER REVERSE DETECTION CURRENT MCU DETECTION 2/8 STAGE SELECT REMOTE CONTROL Bank OK Charging OK 95 100 115 INPUT VOLTAGE (VAC) 60Hz File Name:PB-600-SPEC 2011-04-20 series Maintain stage 8 PFC : 95KHz +V RC RY13 RY15 Ta=25 264 ...

Page 4

... Stage 8/3/2 OFF 10 + Power Stage 8/3 Power Stage 8/3 PB-600 The Function of LEDs Battery Color of LED Fail Charging Battery Full SW - Battery - Battery - Battery File Name:PB-600-SPEC 2011-04-20 series Red Orange Green CN100 RY13 RY13 RY15 RY15 GND RTH 9 10 RC- RC+ CN100 RY13 RY13 ...

Page 5

... Stage 8/3 Battery PB-600 1 RY13 NC RY15 GND 9 RC- - RY13 1 NC RY15 GND RC NTC The temperature sensor can either be attached to the battery or placed in its surrounding environment. File Name:PB-600-SPEC 2011-04-20 series CN100 2 RY13 NC RY15 RTH 10 RC+ RY13 CN100 RY13 2 NC RY15 RTH RC+ 10 ...

Related keywords