EWR1601-0G POWER ONE, EWR1601-0G Datasheet - Page 3

DC/DC Converters & Regulators

EWR1601-0G

Manufacturer Part Number
EWR1601-0G
Description
DC/DC Converters & Regulators
Manufacturer
POWER ONE
Datasheet

Specifications of EWR1601-0G

Output Power
120 W
Input Voltage Range
66 V to 150 V
Input Voltage (nominal)
110 V
Number Of Outputs
1
Output Voltage (channel 1)
24.7 V
Output Current (channel 1)
5 A
Package / Case Size
103 mm x 114 mm x 138 mm
Output Type
Regulated
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Part Number Description
Type specification .................................................. 000 – 999
Operational ambient temperature range T
Improved EMC performance ................................................ E
Options
BCD20020-G Rev AB1, 17-Nov-09
Table 2: Battery charger models (M1 included)
Input voltage range .......................................................... E, L
Series .................................................................................. W
Nominal output power
Number of outputs ............................................................ 1, 2
Example:
* Version 106 or higher
1
2
3
4
5
6
7
8
1
2
[VDC]
V
Setting voltage (typ.) with open R-input
For derating at low input voltage see section Output Power Derating.
For minimum quantity and lead times consult Power-One.
The converters have been tested up to 440 Hz; for operating frequency <47 Hz or >63 Hz contact Power-One.
Nominal output figures, calculated with a cell voltage of 2.27 V at 20 °C.
Improved EMC performance. Former models without E are still available on request.
V
Min. efficiency at V
G is always placed at the end of the part number. Consult Power-One for availability !
Only one of these options is possible.
12
24
36
48
Bat
i
250 VDC for models with option F.
Output Voltage
125 W .............................................................. R
250 W .............................................................. N
–40 to 60 °C ................................................... -6
EW or customer-specific ........................... -0, -5
Output voltage control input
Save data signal
Multiple functions via D-SUB connector
Built-in second fuse, input diode ................. F, Q
System connector .......................................... K2
RoHS compliant for all six substances .......... G
LWN2660-6ED2FK2G: Power factor corrected AC-DC converter, operating input voltage range 85 – 264 VAC,
2 electrically isolated and individually regulated outputs, each providing 24.7 V, 5 A, improved EMC performance,
options D2, F, K2, and RoHS-compatible for all 6 substances.
V
25.68
38.52
51.36
[VDC]
13.8
o safe
1
1
1
1
1
i nom
®
, V
[VDC]
V
14.65
43.95
o nom
58.6
29.3
o max
2 ..........................................
, I
o nom
, and T
V
[VDC]
40.88
o nom
13.8
27.3
54.5
2 .......................................
Nominal Output Values
A
A
5
= 25 °C. Typical values are approx. 2% better.
125, 250 Watt AC-DC and DC-DC DIN-Rail Converters
I
o nom
D1, D2, D5
7.5 *
2 ..
14*
[A]
4.2
8.4
2.8
5.6
2.1
4.2
M1, M2
5
Page 3 of 25
R
1
P
104*
194*
o nom
[W]
115
230
115
230
115
230
5
Operating Input
90
85
47 – 63 Hz
V
2
2
i min
Voltage
– 350 VDC
– 264 VAC,
- V
i max
4
,
7
L W N 2 660 -6 E D2 F K2 G
Type Designation
LWR1140-6EM1
LWN1140-6EM1
LWR1840-6EM1
LWN1840-6EM1
LWR1240-6EM1
LWN1240-6EM1
LWR1740-6EM1
LWN1740-6EM1
W Series Data Sheet
3
3
3
3
6
www.power-one.com
Effic. Options
83*
85*
[%]
min
86
86
85
86
86
87
8
K2, G
F
3

Related parts for EWR1601-0G