LPF-40-30 Mean Well, LPF-40-30 Datasheet

Linear & Switching Power Supplies 40.2W 30V 1.34A LED PS W/PFC

LPF-40-30

Manufacturer Part Number
LPF-40-30
Description
Linear & Switching Power Supplies 40.2W 30V 1.34A LED PS W/PFC
Manufacturer
Mean Well
Datasheet

Specifications of LPF-40-30

Product
Switching
Commercial/medical
Commercial
Output Power Rating
40.2 W
Input Voltage
90 VAC to 305 VAC
Number Of Outputs
1
Output Voltage (channel 1)
30 V
Output Current (channel 1)
1.34 A
Mounting Style
Wire Leads
Dimensions
162.5 mm L x 42.5 mm W x 32 mm H
Open Frame/enclosed
Enclosed
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
OTHERS
NOTE
DC VOLTAGE
CONSTANT CURRENT REGION
RATED CURRENT
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER CURRENT
SHORT CIRCUIT
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
DIMENSION
PACKING
40W Single Output Switching Power Supply
Note.5
Note.3
Note.4
Note.7
Note.6
Note.2
Note.4
LPF-40-12
12V
7.2 ~12V
3.34A
40.08W
150mVp-p
1000ms, 80ms / 115VAC at full load
16ms/230VAC
90 ~ 305VAC
47 ~ 63Hz
PF>0.97/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
0.44Kg; 32pcs/15.08Kg/0.56CUFT
COLD START 75A/230VAC
<0.75mA / 240VAC
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed.
Protection type : Shut down and latch off o/p voltage, re-power on to recover
90
Protection type : Shut down o/p voltage, re-power on to recover
-40 ~ +70
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750,
I/P-O/P:3.75KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level(surge 2KV), criteria A
438.8Khrs min.
162.5*42.5*32mm (L*W*H)
84%
0.6A / 115VAC
15 ~ 17V
4.0%
0.5%
2.0%
0.03%/
10
EN61347-1, EN61347-2-13 independent
(0 ~ 50 )
(RTH2)
(Refer to "Derating Curve")
LPF-40-15
15V
9 ~ 15V
2.67A
40.08W
150mVp-p
17.5 ~ 21V
85%
4.0%
0.5%
1.5%
127 ~ 431VDC
MIL-HDBK-217F (25 )
16ms/115VAC at full load
0.3A / 230VAC
LPF-40-20
20V
12 ~ 20V
2A
40W
150mVp-p
86%
23 ~ 27V
4.0%
0.5%
1.0%
1200ms, 80ms / 230VAC
LPF-40-24
24V
14.4 ~ 24V
1.67A
40.08W
150mVp-p
87%
28 ~ 35V
4.0%
0.5%
0.5%
, IP67 approved
LPF-40-30
30V
18 ~ 30V
1.34A
40.2W
200mVp-p
34 ~ 40V
88%
4.0%
0.5%
0.5%
IP67
; Design refer to UL60950-1, TUV EN60950-1
LPF-40-36
36V
21.6 ~ 36V
1.12A
40.32W
250mVp-p
88%
41 ~ 49V
4.0%
0.5%
0.5%
L P F - 4 0
LPF-40-42
42V
25.2 ~ 42V
0.96A
40.32W
250mVp-p
88.5%
46 ~ 54V
4.0%
0.5%
0.5%
File Name:LPF-40-SPEC 2011-05-10
LPF-40-48
48V
28.8 ~ 48V
0.84A
40.32W
250mVp-p
90%
54 ~ 63V
4.0%
0.5%
0.5%
s e r i e s
LPF-40-54
54V
32.4 ~ 54V
0.76A
41.04W
350mVp-p
59 ~ 66V
90%
4.0%
0.5%
0.5%

Related parts for LPF-40-30

LPF-40-30 Summary of contents

Page 1

... Curve" EN61347-1, EN61347-2-13 independent , IP67 approved MIL-HDBK-217F ( IP67 LPF-40-30 LPF-40-36 LPF-40-42 LPF-40-48 30V 36V 42V 48V 18 ~ 30V 21.6 ~ 36V 25.2 ~ 42V 28.8 ~ 48V 1.34A 1.12A 0.96A 0.84A 40.32W 40.32W 40 ...

Page 2

... Static Characteristics 100 (HORIZONTAL Case No. 976A 600 20 3.5 UL1007 16AWG 60 RECTIFIERS & FILTER O.L.P. DETECTION CIRCUIT O.V.P. 90 100 125 135 145 155 165 175 175 180 INPUT VOLTAGE (V) 60Hz File Name:LPF-40-SPEC 2011-05- Unit:mm +V(Red) -V(Black) Fosc : 100KHz +V -V 200 230 305 ...

Page 3

... Single Output Switching Power Supply Power Factor Characteristic Constant Current Mode LOAD EFFICIENCY vs LOAD (48V Model) LPF-40 series possess superior working efficiency that up to 90% can be reached in field applications 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD DRIVING METHODS OF LED MODULE There are two major kinds of LED drive method "direct drive" and "with LED driver". ...

Related keywords