Specifications of RQ-85D

Product
Switching
Commercial/medical
Commercial
Output Power Rating
30 W
Input Voltage
88 VAC to 264 VAC, 125 VDC to 373 VDC
Number Of Outputs
4
Output Voltage (channel 1)
5 V
Output Current (channel 1)
6 A
Output Voltage (channel 2)
12 V
Output Current (channel 2)
2 A
Output Voltage (channel 3)
24 V
Output Current (channel 3)
1 A
Mounting Style
Chassis
Output Type
DC
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note 7)
OTHERS
NOTE
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
OUTPUT NUMBER
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
EMI CONDUCTION & RADIATION
85W Quad Output Switching Power Supply
Note.6
Note.6
Note.2
Note.3
Note.5
Note.4
RQ-85B
CH1
5V
7A
2 ~ 10A
80.7W
80mVp-p 120mVp-p 100mVp-p
CH1: 4.75 ~ 5.5V
500ms, 20ms/230VAC
100ms/230VAC
88 ~ 264VAC
47 ~ 63Hz
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-25 ~ +70
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
206.8Khrs min.
159*97*38mm (L*W*H)
76%
2.5A/115VAC
COLD START 40A/230VAC
<2mA / 240VAC
CH1: 5.75 ~ 6.75V
0.6Kg; 24pcs/15.4Kg/0.7CUFT
2.0%
0.5%
1.0%
0.03%/
CH2
12V
3.1A
0.3 ~ 4A 0 ~ 1A
+7,-3%
(0 ~ 50 )on +5V output
1.0%
3.0%
(Refer to output load derating curve)
I/P-FG:1.5KVAC
125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
MIL-HDBK-217F (25 )
1.5A/230VAC
CH3
-5V
0.5A
18ms/115VAC at full load
8.0%
1.0%
6.0%
1200ms, 30ms/115VAC at full load
CH4
-12V
0.5A
0 ~ 1A
80mVp-p
5.0%
1.0%
2.0%
O/P-FG:0.5KVAC
RQ-85C
CH1
5V
7A
2 ~ 10A
82.5W
80mVp-p 120mVp-p 100mVp-p
CH1: 4.75 ~ 5.5V
77%
2.0%
0.5%
1.0%
CH2
15V
2.5A
0.3 ~ 4A 0 ~ 1A
+3,-7%
1.0%
3.0%
CH3
-5V
0.5A
8.0%
1.0%
6.0%
CH4
-15V
0.5A
0 ~ 1A
80mVp-p
5.0%
1.0%
2.0%
RQ-85D
CH1
5V
6A
2 ~ 10A
84W
80mVp-p
CH1: 4.75 ~ 5.5V
R Q - 8 5
78%
2.0%
0.5%
1.0%
CH2
12V
2A
0.3 ~ 4A
120mVp-p
+7,-3%
File Name:RQ-85-SPEC 2010-10-18
1.0%
3.0%
CH3
24V
1A
0.1 ~ 1.5A
150mVp-p
8.0%
1.0%
5.0%
s e r i e s
CH4
-12V
0.5A
0 ~ 1A
80mVp-p
5.0%
1.0%
2.0%