RPT-60B Mean Well, RPT-60B Datasheet - Page 2

Linear & Switching Power Supplies 50W 5V/4A 12V/2A -12V/0.5A

RPT-60B

Manufacturer Part Number
RPT-60B
Description
Linear & Switching Power Supplies 50W 5V/4A 12V/2A -12V/0.5A
Manufacturer
Mean Well
Datasheet

Specifications of RPT-60B

Product
Switching
Commercial/medical
Medical
Output Power Rating
20 W
Input Voltage
90 VAC to 264 VAC, 127 VDC to 370 VDC
Number Of Outputs
3
Output Voltage (channel 1)
5 V
Output Current (channel 1)
4 A
Output Voltage (channel 2)
12 V
Output Current (channel 2)
2 A
Output Voltage (channel 3)
- 12 V
Output Current (channel 3)
0.5 A
Mounting Style
Chassis
Output Type
DC
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note 5)
OTHERS
NOTE
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
OUTPUT NUMBER
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
PEAK LOAD(10sec.)
RIPPLE & NOISE (max.)
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
EMI CONDUCTION & RADIATION
60W Triple Output Medical Type
Note.4
Note.3
Note.2
RPT-60D
CH1
5V
3.5A
0.5 ~ 3.85A
47.5W
52.25W
80mVp-p
+3,-2%
200ms, 15ms/230VAC
70ms/230VAC
90 ~ 264VAC
47 ~ 63Hz
0.15Kg; 96pcs/15.4Kg/0.89CUFT
79%
115 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1: 5.75 ~ 6.75V
Protection type : Shut down o/p voltage, re-power on to recover
-20 ~ +65
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1, UL60601-1, TUV EN60601-1, IEC60601-1 approved
I/P-O/P:4KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55011(CISPR11),EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A
677.8Khrs min.
101.6*50.8*29mm (L*W*H)
1.1A/115VAC
COLD START 60A/230VAC
For earth <200uA/264VAC, For patient <100uA/264VAC
0.5%
1.5%
0.03%/
(0 ~ 45 )
(Refer to output load derating curve)
127 ~ 370VDC
I/P-FG:1.5KVAC
MIL-HDBK-217F (25 )
15ms/115VAC at full load
0.7A/230VAC
CH2
24V
1A
0.1 ~ 1.1A
150mVp-p
6.0%
2.0%
3.0%
200ms, 15ms/115VAC at full load
30A/115VAC
O/P-FG:1.5KVAC
CH3
12V
0.5A
0.1 ~ 0.55A
80mVp-p
8.0%
2.0%
4.0%
RPT-6003
CH1
3.3V
5A
0.5 ~ 5.5A
39.9W
43.9W
80mVp-p
+3,-2%
75%
CH1: 3.8 ~ 4.45V
0.5%
1.5%
R P T- 6 0
CH2
5V
3A
0.3 ~ 3.3A
80mVp-p
8.0%
1.0%
2.0%
EN60601-1
IEC60601-1
File Name:RPT-60-SPEC 2011-03-31
CH3
12V
0.7A
0.1 ~ 0.77A
80mVp-p
+10,-6%
+5.5,-5%
2.0%
s e r i e s

Related parts for RPT-60B