FNR-5-12G POWER ONE, FNR-5-12G Datasheet - Page 5

no-image

FNR-5-12G

Manufacturer Part Number
FNR-5-12G
Description
Linear & Switching Power Supplies 19" Rack for 5x 12V Front End
Manufacturer
POWER ONE
Datasheet

Specifications of FNR-5-12G

Product
Mounting Hardware
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Safety, Regulatory, and EMI Specifications
Environmental Specifications
Reliability
BCD20034-G Rev. AD, 11-May-10
Altitude
Operating Temperature
Storage Temperature
Temperature Coefficient
Relative Humidity
Shock
Vibration
Agency Approvals
Electromagnetic
Interference
Harmonics
Voltage Fluctuation
and Flicker
ESD Susceptability
Radiated
Susceptability
EFT/Burst
Input Transient
Protection
RF Conducted
Disturbances
Voltage Interruptions
Voltage Sag Immunity
Leakage Current
MTBF
Parameter
Parameter
Parameter
UL60950-1 (UL), CSA C22.2 60950-1 (cUL), EN60950-1 (TUV), IEC60950-1 and CE (LVD)
FCC CFR title 47 Part 15
Sub-Part B,
EN55022/CISPR 22.
Per IEC61000-3-2.
Per IEC61000-3-3.
Per EN61000-4-2, Level 4. Criterion B
Per EN 61000-4-3, Level 3. Criterion A
Per EN 61000-4-4, Level 4. Criterion B
Per EN 61000-4-5, Class 3. Criterion B Line-to-Line:
Per EN 61000-4-6, Level 3. Criterion A
Per EN 61000-4-11, performance criterion B 30%.
Per EN 61000-4-11, performance criterion C 60%.
Per EN 61000-4-11, performance criterion C 95%.
Per SEMI F47-0999 > 100 VAC.
No output voltage interruption.
Per EN60950-1.
FNP600-12:
FNP850-12:
FNP600-48:
FNP1000-48:
FNP850-12R:
(Calculated) MILHDBK 217F Ground Benign.
Demonstrated.
Useful Life.
Conditions/Description
Conditions/Description
& FNR-5-12G/FNR-5-48G Power Shelves Data Sheet
Operating.
Non-Operating.
Internal DC fan for cooling. At 100% load:
Internal DC fan for cooling. At 100% load:
0 ºC to 70 ºC (after 15-minute warm-up).
Non-condensing
Operating: half-sine, 10 ms, 3-axis.
Non-Operating: half-sine, 10 ms, 3-axis.
Operating: swept sine 5-2000-5 Hz, 5-32
Hz, 0.02îDA, 32-2000 Hz.
Non-operating: random 10-2000 Hz.
Page 5 of 15
Conditions/Description
Line-to-Ground:
At 240 VAC:
Conducted:
Radiated:
FNP600/850/1000 AC-DC Front-Ends
At 50% load:
At 94% load:
At 50% load:
100 000
250 000
Min.
Pass
Min.
100
10
±4
10
10
10
B
A
A
8
1
2
5
Min.
Nom.
Nom.
-40
0
0
0
0
0
Nom.
www.power-one.com
Max.
Max.
3.5
.
.
.
.
.
.
.
Max.
0.02
6.15
10K
40K
+20
+40
50
70
40
50
70
85
95
1
Units
Units
Class
Class
V/M
Sec
mA
hrs
hrs
ms
ms
yrs
kV
kV
kV
Units
ASL ft
ASL ft
V
Grms
%/ºC
%RH
Gpk
Gpk
Gpk
ºC
ºC
ºC

Related parts for FNR-5-12G