MAP55-4002 POWER ONE, MAP55-4002 Datasheet

no-image

MAP55-4002

Manufacturer Part Number
MAP55-4002
Description
Linear & Switching Power Supplies Book as (MAPxx-xxxx)
Manufacturer
POWER ONE
Type
Commercial, Industrialr
Datasheet

Specifications of MAP55-4002

Brand/series
MAP55 Series
Configuration
Open-Frame
Current, Input
1.6 A (RMS) @ 90 VAC
Current, Leakage
500 μA (Max.)
Dimensions
6 in. L x 3.27 in. W
Hold Time
20 mS (Min.)
Mounting Type
Panel
Number Of Outputs
4
Operation
Switching
Output
-12 VDC @ 0.5 A, +5 VDC @ 6 A, +12 VDC @ 0.5 A, +12 VDC @ 3 A
Power, Output
55 W
Power, Rating
55 W (Continuous)
Primary Type
AC-DC
Temperature, Operating
50 °C
Voltage, Input
110/220 VAC
Voltage, Output
-12, +5, +12, +12 VDC
Voltage, Output 1
5 V
Voltage, Output 2
-5 V
Voltage, Output 3
12 V
Voltage, Output 4
-12 V
En61000-4-2 Esd Level 4 (8 Kv)
All Map Products
En61000-4-3 Radiated Level 3 (10 V/m)
All Map Products
Universal Input
90-132 VAC or 175-264 VAC
Output Current (max)
6/3/0.5/0.5A
Input Voltage
90 to 132/175 to 264V
Output Voltage
5/12/-12/12V
Output Power (max)
55W
Input Frequency
47 to 63Hz
Efficiency
73%
Screening Level
Commercial
Product Length (mm)
83.1mm
Product Height (mm)
40.6mm
Product Depth (mm)
152.4mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
70C
Mounting Style
Screw
Pin Count
11
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
JUL 14, 2006 revised to AUG 10, 2006
Single-Output Model Selection
NOTES:
Multiple-Output Model Selection
NOTES: 1) Peak loads up to 65 watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 65 watts.
Power-One's MAP55 Series of power supplies provides reliable, tightly-regulated DC power for commercial and
industrial systems. Wide-range AC input and full international safety, EMI, and ESD compliance ensure worldwide
acceptance. All units bear the CE Mark.
The MAP55 utilizes a thermally efficient U-channel chassis design, which allows full power operation in convection-
cooled applications. Other mechanical design innovations include metric and SAE mounting inserts on each mounting
surface to provide integration flexibility. Dual-mode connectors provide traditional terminal block connections or popular
single row Molex connector mating.
Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output
voltage requirements.
Description
MAP40-1005
MAP55-1012 12V/15V
MAP55-1024 24V/28V
MODEL
MAP55-4000
MAP55-4001
MAP55-4002
MAP55-4003
MAP55-4004
MODEL
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
3) Maximum load on V3 or V4 could be 1 amp continuous if output V4 or V3 is unloaded.
1) Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
2) MAP55-1012 output currents are expressed as 12V/15V operation. MAP55-1024 output currents are expressed as 24V/28V operation.
3) Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum.
VOLTAGE
OUTPUT
VOLTAGE
OUTPUT
+12V
+24V
+12V
+12V
+12V
+15V
+24V
+15V
-12V
-12V
-12V
-15V
-15V
+5V
+5V
+5V
+5V
+5V
5V
-5V
-5V
11.4V to 15.75V
23.5V to 28.5V
4.7V to 5.50V
ADJUSTMENT
4.7V to 5.6V
4.7V to 5.6V
4.7V to 5.6V
4.7V to 5.6V
4.7V to 5.6V
ADJUSTMENT
RANGE
RANGE
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
55W Continuous Output Power
5.0/4.0A (Note 2)
2.5/2.2A (Note 2)
MAXIMUM OUTPUT
CURRENT
CURRENT
OUTPUT
8A
0.5A
0.5A
1.5A
0.5A
0.5A
0.5A
0.5A
2.5A
0.5A
0.5A
1.5A
0.5A
0.5A
6A
3A
6A
6A
3A
6A
6A
Page 1 of 3
5.8/4.7A (Note 2)
2.9/2.5A (Note 2)
CURRENT (NOTE 3)
CURRENT (NOTE 1)
1A (Note 3)
1A (Note 3)
1A (Note 3)
1A (Note 3)
1A (Note 3)
1A (Note 3)
1A (Note 3)
1A (Note 3)
1A (Note 3)
1A (Note 3)
PEAK OUTPUT
PEAK OUTPUT
2.5A
3.5A
2.5A
11A
8A
5A
8A
8A
5A
8A
8A
Features
MAP55 AC-DC Series Data Sheet
RoHS lead-solder-exempt compliant
Wide Range Input for 110/220 VAC Applications
Meets EN55022, Conducted Class B Limits
Compact Footprint: 6.00" x 3.27" x 1.60"
(152.4mm x 83.1mm x 40.6mm)
Greater than 225,000 Hours MTBF
Metric and SAE Mounting Inserts
REGULATION
REGULATION
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.2%
LINE
LINE
REGULATION
REGULATION
±1.5%
±1%
LOAD
LOAD
1%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
RIPPLE & NOISE
RIPPLE & NOISE
%p-p (NOTE 2)
%p-p (NOTE 1)
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
www.power-one.com
-11.6V to -12.4V
-11.6V to -12.4V
-11.6V to -12.4V
-14.4V to -15.6V
-14.5V to -15.5V
11.6V to 12.4V
23.0V to 24.9V
11.6V to 12.4V
11.6V to 12.4V
11.6V to 12.4V
14.6V to 15.4V
23.0V to 24.9V
14.5V to 15.5V
-4.8V to -5.2V
-4.8V to -5.2V
12.0V to 12.2V
23.8V to 24.2V
INITIAL SETTING
5.0V to 5.2V
5.0V to 5.2V
5.0V to 5.2V
5.0V to 5.2V
5.0V to 5.2V
INITIAL SETTING
5.0V to 5.2V
ACCURACY
ACCURACY

Related parts for MAP55-4002

MAP55-4002 Summary of contents

Page 1

... Fixed MAP55-4000 -5V Fixed -12V Fixed +5V 4.7V to 5.6V MAP55-4001 +24V Fixed -12V Fixed +12V Fixed +5V 4.7V to 5.6V +12V Fixed MAP55-4002 -12V Fixed +12V Fixed +5V 4.7V to 5.6V +15V Fixed MAP55-4003 -5V Fixed -15V Fixed +5V 4.7V to 5.6V +24V Fixed MAP55-4004 -15V Fixed ...

Page 2

... Turn-on Delay Time required for initial output voltage stabilization. Turn-on Rise Time Time required for output voltage to rise from 10% to 90% (Note 1). NOTES: 1) Nominal rise time for MAP55-1024 is 36 msec. Interface Signals and Internal Protection PARAMETER CONDITIONS/DESCRIPTION Overvoltage Protection Overload Protection Fully protected against output overload and short circuit ...

Page 3

... Add ‘C’ suffix to model number or order part number 412-59584-G separately. For convection cooled applications, derate output power to 45 watts on multiple output units, 50 watts on MAP55-1012 and MAP55-1024,and 40 watts on MAP40-1005. OVERALL SIZE: 6.00" x 3.27" x 1.60" (152.4mm x 83.1mm x 40.6mm) INPUT & OUTPUT CONNECTIONS: CHASSIS: 0.090" ...

Related keywords