ADS-15548 Mean Well, ADS-15548 Datasheet

no-image

ADS-15548

Manufacturer Part Number
ADS-15548
Description
Linear & Switching Power Supplies 154.2W 2.9A 48V 3A 5Vout
Manufacturer
Mean Well
Datasheet

Specifications of ADS-15548

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
OUTPUT NUMBER
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
EMI CONDUCTION & RADIATION
155W Single Output with 5V, 3A DC-DC Converter
Note.3
Note.2
ADS-15512
CH1
12V
11.5A
0 ~ 12.5A
153W
150mVp-p
CH1:10.8 ~ 13.2V
1000ms, 90ms/230VAC
24ms/230VAC
88 ~ 264VAC
47 ~ 63Hz
PF>0.92
2.5A/115VAC
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is reoved
CH1:13.8 ~ 16.2V
Protection type : Shut down o/p voltage, re-power on to recover
-10 ~ +60
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to
202.3K hrs min.
199*110*50mm (L*W*H)
1Kg; 16pcs/16Kg/0.95CUFT
77%
COLD START 20A/115VAC
<1mA / 240VAC
2.0%
0.5%
1.0%
0.03%/
(0 ~ 50 )
(Refer to output load derating curve)
EN61000-4-2,3,4,5,6,8,11; ENV50204,
I/P-FG:1.5KVAC
124 ~ 370VDC
1.5A/230VAC
MIL-HDBK-217F (25 )
20ms/115VAC at full load
CH2
5V
3A
0 ~ 3A
100mVp-p
3.0%
0.5%
2.0%
2000ms, 90ms/115VAC at full load
40A/230VAC
O/P-FG:0.5KVAC
ADS-15524
CH1
24V
5.8A
0 ~ 6.5A
154.2W
150mVp-p
CH1:21.6 ~ 26.4V
CH1:27.6 ~ 32.4V
82%
1.0%
0.5%
0.5%
EN55024, light industry level, criteria A
CH2
5V
3A
0 ~ 3A
100mVp-p
3.0%
0.5%
2.0%
A D S - 1 5 5
ADS-15548
CH1
48V
2.9A
0 ~ 3.2A
154.2W
240mVp-p
CH1:43.2 ~ 52.8V
CH1:55.2 ~ 64.8V
82%
1.0%
0.5%
1.0%
File Name:ADS-155-SPEC 2010-10-18
CH2
5V
3A
0 ~ 3A
100mVp-p
5.0%
0.5%
1.0%
s e r i e s

Related parts for ADS-15548

ADS-15548 Summary of contents

Page 1

... CH1:27.6 ~ 32.4V (Refer to output load derating curve) 0.03 I/P-FG:1.5KVAC O/P-FG:0.5KVAC EN61000-4-2,3,4,5,6,8,11; ENV50204, MIL-HDBK-217F ( ADS-15548 CH2 CH1 5V 48V 3A 2. 3.2A 154.2W 100mVp-p 240mVp-p CH1:43.2 ~ 52.8V 3.0% 1.0% 0.5% 0.5% 2 ...

Page 2

... PFC fosc : 67KHz PWM fosc : 134KHz SWITCHING REGULATOR RECTIFIERS & FILTER CONSTANT CURRENT LIMITING & DETECTION CIRCUIT O.V.P. 90 100 120 140 160 180 200 220 INPUT VOLTAGE (V) 60Hz File Name:ADS-155-SPEC 2010-10- Unit:mm Assignment NC DC OUTPUT COM DC OUTPUT +V + +12V 240 260 ...