MAP40-3003 POWER ONE, MAP40-3003 Datasheet

no-image

MAP40-3003

Manufacturer Part Number
MAP40-3003
Description
Linear & Switching Power Supplies 40W +5V/3A,+15V/1.5A -15V/0.2A
Manufacturer
POWER ONE
Type
Commercial, Industrialr
Datasheets

Specifications of MAP40-3003

Product
Switching
Brand/series
MAP40 Series
Configuration
Open-Frame
Current, Input
1.2 A (RMS) @ 90 VAC
Current, Inrush
38 A (Max.) (Surge)
Hold Time
15 ms (Min.) @ 90 VAC
Mounting Type
Panel
Number Of Outputs
3
Operation
Switching
Output
-15 VDC @ 0.2 A, +5 VDC @ 3 A, +15 VDC @ 1.5 A
Power, Output
40 W
Power, Rating
40 W
Primary Type
AC-DC
Standards
UL Listed, CSA Certified, TUV Approved
Temperature Coefficient
±0.02%⁄°C (Nom.)
Temperature, Operating
0 °C
Voltage, Input
90 to 264 VAC
Voltage, Output
-15, +5, +15 VDC
Voltage, Output 1
5 V
Voltage, Output 2
15 V
Voltage, Output 3
-15 V
En61000-4-2 Esd Level 4 (8 Kv)
All Map Products
En61000-4-3 Radiated Level 3 (10 V/m)
All Map Products
Universal Input
90-132 VAC or 175-264 VAC
Output Current (max)
3/1.5/0.2A
Input Voltage
85 to 264V
Output Voltage
5/15/-15V
Output Power (max)
40W
Input Frequency
47 to 63Hz
Efficiency
70%
Screening Level
Commercial
Product Length (mm)
76.2mm
Product Height (mm)
29.5mm
Product Depth (mm)
127mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
50C
Mounting Style
Screw
Pin Count
8
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
REV. JUN 19, 2006 revised to APR 13, 2007
Description
Power-One’s MAP30/40/42 Series of power supplies combines low cost and universal input in a board-only power
solution to meet commercial and industrial requirements. Full international safety, EMI, and ESD compliance ensure
worldwide acceptance. All units bear the CE Mark.
Fixed frequency operation simplifies system level operation. The MAP30/40/42 Series is configured to the international
standard 3.00" x 5.00" footprint. Input and output connections are made via popular single-row Molex connectors.
Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output
voltage requirements.
Single-Output Model Selection
MAP30-1005
MAP42-1005
MAP42-1012
MAP42-1024
NOTES: 1) Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
Multiple-Output Model Selection
NOTES :
MODEL
MAP40-3000
MAP40-3100
MAP40-3101
MAP40-3105
MAP40-3500
MAP40-3003
MODEL
Model numbers highlighted in yellow or shaded are not recommended for new designs.
2) Peak ratings may be used as maximum output current with 100 Linear Feet per Minute (LFM) forced air cooling.
3) MAP42-1012 output currents are expressed as 12V/15V operation. MAP42-1024 output currents are expressed as 24V/28V operation.
1) Peak loads for 30 seconds or less are acceptable, (10% duty cycle max.).
2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
3) Quasi regulated output. See Regulation Curves for more information.
4) Requires a minimum load of 0.5A on V1 or 0.3A on V2.
12V/15V
24V/28V
VOLTAGE
OUTPUT
VOLTAGE
OUTPUT
+12V
+12V
+24V
+12V
+15V
-12V
-12V
-12V
-12V
-15V
+5V
+5V
+5V
+5V
+5V
+5V
5V
5V
+12
-5V
11.0V to 18.0V
23.0V to 29.0V
4.7V to 5.8V
4.7V to 5.8V
4.75V to 5.50V
4.75V to 5.25V
4.75V to 5.25V
ADJUSTMENT
4.7V to 5.8V
4.7V to 5.8V
4.7V to 5.8V
ADJUSTMENT
RANGE
RANGE
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
3.4/2.7A (Note 3)
1.7/1.4A (Note 3)
40W CONTINUOUS OUTPUT POWER
MAXIMUM OUTPUT
CURRENT
CURRENT
OUTPUT
6A
8A
0.3A
0.3A
0.3A
0.5A
0.3A
1.5A
0.2A
3A
2A
3A
2A
3A
1A
3A
2A
5A
1A
3A
Page 1 of 5
4.6/3.7A (Note 3)
2.3/1.9A (Note 3)
CURRENT (NOTE 2)
CURRENT (NOTE 1)
MAP30/40/42 AC-DC Series Data Sheet
PEAK OUTPUT
PEAK OUTPUT
3.5A
0.5A
3.5A
0.5A
1.5A
0.5A
3.5A
1.0A
3.5A
0.5A
0.5A
11A
8A
5A
5A
5A
5A
6A
5A
3A
Features
• RoHS lead-solder-exemption compliant
• Universal input 85-264 VAC
• CE marked to Low Voltage Directive
• Input transient & ESD compliance to
• Meets EN55022 conducted and radiated limits
• Greater than 311,000 Hours MTBF
• Remote sense (MAP30, MAP42)
EN61000-4-2/-3/-4
REGULATION
REGULATION
0.2%
0.2%
0.2%
0.2%
0.2%
0.2%
0.2%
0.2%
0.2%
0.2%
LINE
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
LINE
3.5% (Note 3)
3.5% (Note 3)
3.5% (Note 3)
3.5% (Note 3)
3.5% (Note 3)
3.5% (Note 3)
2% (Note 4)
2% (Note 4)
REGULATION
REGULATION
LOAD
±1%
±1%
LOAD
1%
1%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
RIPPLE & NOISE
RIPPLE & NOISE
%p-p (NOTE 2)
%p-p (NOTE 1)
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
www.power-one.com
-11.4V to -12.6V
-11.4V to -12.6V
-11.5V to -12.5V
-4.75V to -5.25V
-11.4V to -12.6V
-14.3V to -15.7V
11.5V to 12.5V
11.5V to 12.5V
23.0V to 25.0V
11.5V to 12.5V
11.5V to 12.5V
14.7V to 15.3V
11.9V to 12.1V
23.8V to 24.2V
INITIAL SETTING
4.9V to 5.1V
4.9V to 5.1V
4.9V to 5.1V
4.9V to 5.1V
4.9V to 5.1V
4.9V to 5.1V
INITIAL SETTING
4.9V to 5.1V
4.9V to 5.1V
ACCURACY
ACCURACY

Related parts for MAP40-3003

MAP40-3003 Summary of contents

Page 1

... MAP40-3500 +12V Fixed -12V Fixed +5V 4.7V to 5.8V MAP40-3003 +15V Fixed -15V Fixed NOTES : 1) Peak loads for 30 seconds or less are acceptable, (10% duty cycle max.). 2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 3) Quasi regulated output. See Regulation Curves for more information. ...

Page 2

... EN61000-4-5 Level 3 Protection Insulation Resistance Input to output. Leakage Current Per EN60950, 264VAC NOTES: 1) MAP30-1005, MAP40-3000, MAP40-3003 meet Class A. 2) MAP40-3000, MAP40-3003, MAP3500 meet Class A. REV. JUN 19, 2006 revised to APR 13, 2007 MAP30/40/42 AC-DC Series Data Sheet MAP42 MAP30, MAP40 MAP30-1005, MAP42-1005 MAP42-1012 MAP42-1024 Main output only of multiple output units ...

Page 3

Environmental Specifications PARAMETER CONDITIONS/DESCRIPTION Altitude Operating. Non-operating. Operating Temperature Derate linearly above 50°C by 2.5% per ° maximum temperature of 70°C. Storage Temperature Temperature Coefficient 0°C to 70°C (after 15 minute warm-up). Relative Humidity Non-condensing. Shock Operating, peak ...

Page 4

... OUTPUT CURRENT PERFORMANCE FOR +12V OUTPUT 0.4 0.6 0.8 1.0 1.2 1.4 1.6 12V OUTPUT CURRENT MAP40-3003 TYPICAL QUASI REGULATION PERFORMANCE FOR +15V OUTPUT 0.3 0.45 0.6 0.75 0.9 1.05 1.2 15V OUTPUT CURRENT Page +5V @ 5.0 Amps +5V @ 3.0 Amps + ...

Page 5

... PIN 6 N GND GND PIN 1 +Sense PIN 1 -Sense CENTER CRIMP TERMINAL HOUSING OR EQUIVALENT MAP30/40/42 SERIES HEIGHT Multiple Output Models Height Model 1.16" (29.5) MAP40-3000 1.25" (31.8) MAP40-3003 1.25" (31.8) MAP40-3100 1.25" (31.8) MAP40-3101 MAP40-3105 MAP40-3500 Page MAP42 J2 V2 PIN GND GND GND ...

Related keywords