GLC65-15 SL Power, GLC65-15 Datasheet

Linear & Switching Power Supplies 65W 15V @ 4.3A

GLC65-15

Manufacturer Part Number
GLC65-15
Description
Linear & Switching Power Supplies 65W 15V @ 4.3A
Manufacturer
SL Power
Series
GLCr
Datasheet

Specifications of GLC65-15

Product
Switching
Commercial/medical
Commercial
Output Power Rating
65 W
Input Voltage
90 VAC to 264 VAC
Number Of Outputs
1
Output Voltage (channel 1)
15 V
Output Current (channel 1)
4.3 A
Mounting Style
Chassis
Dimensions
115.82 mm L x 76.2 mm W
Open Frame/enclosed
Open Frame
Output Type
Single Output
Output Current (max)
4.3A
Output Voltage
15V
Output Power (max)
65W
Input Frequency
47 to 63Hz
Screening Level
Commercial
Product Length (mm)
127mm
Product Depth (mm)
76.2mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
50C
Pin Count
11
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
• 4.1 W/in3
• Compact (3.0” x 5.0” x 1.06”)
• Ultra-high efficiency (up to 94%) using patented
• Meets harmonic requirements of IEC1000-3-2, Class A
• Conducted EMI exceeds FCC Class B and CISPR 22
• 2-year warranty
• Exempt from line harmonics standard EN61000-3-2
• Commercial Approved to UL1950, IEC950, EN60950,
• Medical Approved to UL2601, EN60601, CSA22.2
• Multiple output versions also available
• RoHS models available (G suffix)
SPECIFICATIONS
GLOBAL PERFORMANCE SWITCHERS
FEATURES:
technology
Class B (Commercial models) and CISPR 11 Class B
(Medical models)
CSA22.2 No. 950
No. 601.1
All specifications are typical at nominal input, full load at 25
Ac Input
90-264 Vac, 47-63 Hz single phase.
Input Current
Maximum input current at minimum output voltage and output overload
will be less than 1.7 A. Meets input current harmonic requirements of
IEC1000-3-2.
Output Power
Normal continuous output power is 65 W, 75 W peak for 60 s. The 3.3 Vdc unit
is 36.3 W and the 5 Vdc unit is 55 W continuous.
Hold-Up Time
20 ms from loss of ac input at 65 W load, from 120 Vac input.
Overload Protection
Fully protected against short circuit and output overload. Short circuit protec-
tion is cycling type power limit.
Output Noise
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with
scope probe directly across output terminals of the power supply with load
terminated with 0.1 μF capacitor.
Transient Response
Main output: 500 μs typical response time for return to within 0.5% of final
value for a 50% load step within the regulation limits of minimum and maxi-
mum load, ∆i/∆t<0.2 A/μs. Maximum voltage deviation is 3.5%. Startup/shut-
down overshoot less than 3%.
Voltage Adjustment
Adjustable potentiometer capable of ±5% change from nominal setting.
Efficiency
82 to 94% minimum at full rated load, nominal input voltage, depending on
model.
Minimum Load
No minimum load required.
marked to LVD
GLC65 Commercial/GLM65 Medical
65 Watt Single Output Global Performance Switchers
O
C unless otherwise stated
Inrush Current
Inrush is limited by internal thermistor. The inrush at 240 Vac, averaged over the
first ac half-cycle under cold start conditions will not exceed 37A.
EMI/EMC Compliance
All models include built-in EMI filtering to meet the following emissions
requirements:
EMI SPECIFICATIONS
Conducted Emissions GLC65
Conducted Emissions GLM65
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Surge Susceptibility
Commercial Leakage Current
Under normal conditions, leakage current is 425 μA with 132 Vac @ 60 Hz input.
Commercial Safety
All GLC models are approved to UL1950, CSA22.2 No. 950, IEC950 and EN60950.
Medical Leakage Current
The maximum leakage current under single-fault conditions (254 Vac @ 50 Hz) is
120 μA. Under normal conditions, leakage current is 31μA with 132 Vac @ 60 Hz
input.
Medical Safety
All GLM models are approved to UL2601, CSA22.2 No. 601, IEC601-1 and EN60601.
Consult factory for approval status.
Temperature Coefficient: 0.03%°C typical on all outputs.
Remote Sense
Provided as standard feature on all models. Includes open sense protection.
COMPLIANCE LEVEL
EN55022 Class B; FCC Class B
EN55011 Class B: FCC Class B
EN61000-4-2, 6 kV contact, 8 kV air
EN61000-4-3, 3 V/meter
EN61000-4-4, 2 kV, 5 kHz
EN61000-4-5, 1 kV diff., 2 kV com.

Related parts for GLC65-15

GLC65-15 Summary of contents

Page 1

... Inrush is limited by internal thermistor. The inrush at 240 Vac, averaged over the first ac half-cycle under cold start conditions will not exceed 37A. EMI/EMC Compliance All models include built-in EMI filtering to meet the following emissions requirements: EMI SPECIFICATIONS Conducted Emissions GLC65 Conducted Emissions GLM65 Static Discharge RF Field Susceptibility Fast Transients/Bursts Surge Susceptibility Commercial Leakage Current Under normal conditions, leakage current is 425 μ ...

Page 2

... Commercial Medical Model Model GLC65-5 GLM65-5 GLC65-12 GLM65-12 GLC65-15 GLM65-15 GLC65-18 GLM65-18 GLC65-20 GLM65-20 GLC65-24 GLM65-24 GLC65-28 GLM65-28 GLC65-48 GLM65-48 • Note convection with fan cooling GLC65/GLM65 - SINGLE OUTPUT - MECHANICAL SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS OPERATING Temperature ( 50° Humidity ( 95% RH Shock ( Altitude -500 to 10,000 ft Vibration (C) 1 ...

Related keywords