Page 1
... NOTES: 1) Typical peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth. 2) MAP130-1012 output currents are expressed as 12V/15V operation. MAP130-1024 output currents are expressed as 24V/28V operation. 3) Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum. Multiple Output Model Selection ...
Page 2
... Multiple Output Model Selection (Cont.) OUTPUT ADJUSTMENT MODEL VOLTAGE RANGE +5V 4.75V to 5.50V +15V 14.0V to 16.0V MAP130-4003 -5V Fixed -15V Fixed +5V 4.75V to 5.50V +24V 23.0V to 25.0V MAP130-4004 -15V Fixed +15V Fixed +5V 4.75V to 5.50V +12V 11.5V to 12.8V MAP130-4010 -5V Fixed -12V Fixed +5V 4.75V to 5.50V +12V 11.5V to 12.8V MAP130-4020 ...
Page 3
... For convection cooled applications with covers, derate output power as follows: Derate all multiple output models and MAP130-1005 to 120 watts. Derate MAP130-1012 and MAP130-1024 to 140 watts. MCD10115 Rev. 1.3, 05-Feb-10 MAP130 AC-DC Series Data Sheet MAP130-1012 MAP130-1024 MAP130-4004 All other models. Line to Line Line to Ground 2 At 100% load: At 50% load: Page ...
Page 4
... TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. MCD10115 Rev. 1.3, 05-Feb-10 MAP130 AC-DC Series Data Sheet WEIGHT: 2.5 lb (1.13 kg) 0.045" (1.1mm) SQUARE PINS ON 0.156" (3.96mm) CENTERS; ...