MWP-610P Mean Well, MWP-610P Datasheet

Plug-In AC Adapters 244W 5V 8A 12V 8A 24V 4.5A W/PFC

MWP-610P

Manufacturer Part Number
MWP-610P
Description
Plug-In AC Adapters 244W 5V 8A 12V 8A 24V 4.5A W/PFC
Manufacturer
Mean Well
Datasheet

Specifications of MWP-610P

Input Voltage (nominal)
100 VAC to 132 VAC, 200 VAC to 264 VAC
Number Of Outputs
3
Output Power Rating
304 W
Output Voltage (channel 1)
5 V
Output Current (channel 1)
1.5 A
Ac Plug Included/required
Required
Commercial/medical
Commercial
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
SPECIFICATION
MODEL NO.
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
AC CURRENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
OVERLOAD
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
HARMONIC CURRENT
EMS IMMUNITY
CONNECTOR
COOLING
DIMENSION
CHANNEL
DC VOLTAGE
MINIMUM CURRENT
RATED CURRENT (CONTINUOUS)
PEAK CURRENT (10 min.)
RATED POWER (CONTINUOUS)
PEAK POWER (10 min.)
RIPPLE & NOISE (max.)
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
HOLD UP TIME
AC RECEPTACLE RATED (max.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
OVER VOLTAGE
EMI CONDUCTION & RADIATION
304W Triple Output for Video Game
Note.2
Note.3
MWP-610P
CH1
5V
1.5A
8A
8A
244W
304W
80mVp-p
12ms min. at full load
1A / 230VAC
200 ~ 264VAC
47 ~ 63Hz
PF>0.7 / 230VAC
Protection type : Shut down o/p voltage, re-power on to recover
105 ~ 140% rated output voltage
Protection type : Shut down o/p voltage, re-power on to recover
4.5A / 230VAC
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-10
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
10 ~ 200Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
Design refer to EN60950-1
I/P-O/P
I/P-O/P
Compliance to EN55022 Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, l
See page 2
Forced air ventilation by 8cm DC fan
150*140*86mm (L*W*H)
76%
80A / 230VAC
3.5mA / 240VAC
105 ~ 200% rated output power
5.0%
1.0%
5.0%
0.05% /
~ +50
, I/P-FG
, I/P-FG
( 0 ~ 50
:1.5KVAC
:50M Ohms / 500VDC
(Refer to output load derating curve)
/ 25 / 70% RH
ight industry level,
CH2
12V
1A
8A
12A
150mVp-p
5.0%
1.0%
5.0%
criteria A
M W P - 6 1 0 P
CH3
24V
0.5A
4.5A
5A
200mVp-p
5.0%
1.0%
5.0%
File Name: MWP-610P-SPEC 2010-04-28

Related parts for MWP-610P

MWP-610P Summary of contents

Page 1

... NOTE CH2 12V 1A 8A 12A 150mVp-p 5.0% 5.0% 1.0% 1.0% 5.0% 5.0% ~ +50 (Refer to output load derating curve) 0.05 I/P-FG :1.5KVAC , I/P-FG :50M Ohms / 500VDC / 25 / 70% RH ight industry level CH3 24V 0.5A 4.5A 5A 200mVp-p 5.0% 1.0% 5.0% criteria A File Name: MWP-610P-SPEC 2010-04-28 ...

Page 2

... Derating Curve 100 - AMBIENT TEMPERATURE ( ) 140 25 Pin No. Assignment Pin No. Assignment 5 +12V 9 +12V 6 GND 10 GND 7 +24V 11 GND 8 +5V 12 +5V Static Characteristics 100 (HORIZONTAL) 200 61.8 350 50 Ta=25 210 220 230 240 INPUT VOLTAGE (VAC) 60Hz File Name: MWP-610P-SPEC 2010-04-28 Unit: mm 264 ...

Related keywords