Plug-In AC Adapters 25W 100-240VAC 3.3V 4.0A 2.1mm DC R/A

TRG25033-U-11E01

Manufacturer Part Number
TRG25033-U-11E01
Description
Plug-In AC Adapters 25W 100-240VAC 3.3V 4.0A 2.1mm DC R/A
Manufacturer
Cincon

Specifications of TRG25033-U-11E01

Mounting Style
Wall
Input Voltage (nominal)
100 VAC to 240 VAC
Number Of Outputs
1
Output Power Rating
25 W
Output Voltage (channel 1)
3.3 V
Output Current (channel 1)
4 A
Dc Output Connector
2.1 mm Barrel Plug
Dc Output Cord Length
720 mm
Ac Plug Included/required
Included
Commercial/medical
Commercial
Efficiency
Level IV
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
INPUT SPECIFICATIONS:
Voltage …....………........…........................................... 90~264Vac
Frequency ………………………………………….……………..... 47 to 63Hz
Inrush Current ………………….……………................... 0.7A max.
Inrush Current ………………….……………................... 50A max. @240Vac
Conducted EMI …………………………….…………... CISPR/FCC Class B
Leakage Current …………………………………………………. 0.25mA max.
OUTPUT SPECIFICATIONS:
Holdup Time ……………………………………………… 10ms typ. @115Vac
Short Circuit Protection …………….…………… Continuous(Auto Recovery)
Over Voltage Protection ………………. ............... TVS Component to Clamp
Temperature Coefficient ……………………............................… ±0.05%/℃
GENERAL SPECIFICATIONS:
Isolation ………………………………….…..…… Input to output = 4,242VDC
Operating Temperature ................................... 0 ~ 60 ℃ (see derating curve)
Storage Temperature ………………….…………...….......……........ -20~85 ℃
Humidity …………………...….......…........... 93% RH max. Non condensing
Cooling ………………………………….………………….. Natural Convection
Switching Frequency ………………………….……………….. 65KHz Typical
MTBF …….… MIL-HDBK-217F, GB, 25 ℃ /115VAC ……… 300K hrs min.
Altitude …………………………………………………………………… 2000m
Dimensions ……….….. 3.169x1.932x2.205Inches (80.5x49.06x56.00mm)
Weight ………………………………………………….…… 280g(0.62 Pounds)
SAFETY AND EMC:
Emission and lmmunity ……….… EN55022 Class B, FCC Part 15 Class B
Safety …………………………….…… IEC60950-1, EN60950-1, UL60950-1
NOTE:
1. Voltage setpoint at 60% full load
2. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for
3. Line regulation measured from 100Vac to 240Vac, full load.
4. Load regulation measured from 60% to 100% full load and from 60% to
5. ”Various TR Series adapters are PSE certified. PSE certification
TRG25 Series Derating Curve
Typical at 25˚C, nominal line and 75% load, unless otherwise Specified
Ripple & Noise measuring @20MHz BW.
20% load (60% +/- 40% full load)
alone is not sufficient for importation into Japan. A valid PSE mark
must contain the name of the importer as shown in the example below.
If PSE mark is required, the name of the registered importer must be
supplied to Cincon on order placement. Product labels will not contain
PSE mark if importer name is not supplied. Consult factory or local
representative for details”
100%
75%
50%
25%
0%
0
10
20LFM(Natural Conv ection)
Specifications
Ambient Temperature(
20
EN61000-6-3, EN61000-3-2, EN61000-3-3
EN55024, EN61204-3, EN61000-6-1
30
40
o
C)
50
60
2
Mechanical Specification