MAX8903GETI+ Maxim Integrated Products, MAX8903GETI+ Datasheet - Page 12

no-image

MAX8903GETI+

Manufacturer Part Number
MAX8903GETI+
Description
Battery Management Dual AC/USB Powered 1-Cell Li+ Charger
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX8903GETI+

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
2A 1-Cell Li+ DC-DC Chargers for USB
and Adapter Power
12
20, 21
23, 24
25, 26
27, 28
PIN
13
14
15
16
17
18
19
22
______________________________________________________________________________________
NAME
USUS
UOK
CHG
ISET
CEN
THM
USB
BAT
SYS
FLT
CS
LX
EP
Charge Current Set Input. A resistor (R
The prequal charge current is 10% of the fast-charge current.
Charger Enable Input. Connect CEN to GND to enable battery charging when a valid source is connected
at DC or USB. Connect to VL, or drive high to disable battery charging.
USB Suspend Input. Drive USUS logic-high to enter USB suspend mode, lowering USB current to 115μA,
and internally shorting SYS to BAT.
Thermistor Input. Connect a negative temperature coefficient (NTC) thermistor from THM to GND.
Connect a resistor equal to the thermistor +25°C resistance from THM to VL. Charging is suspended
when the thermistor is outside the hot and cold limits. Connect THM to GND to disable the thermistor
temperature sensor.
USB Power Input. USB is capable of delivering 100mA or 500mA to SYS as set by the IUSB logic input.
Connect a 4.7μF ceramic capacitor from USB to GND.
Fault Output. Active-low, open-drain output pulls low when the battery timer expires before prequal or
fast-charge completes.
USB Power-OK Output. Active-low, open-drain output pulls low when a valid input is detected at USB.
UOK is still valid when the charger is disabled (CEN high).
Battery Connection. Connect to a single-cell Li+ battery. The battery charges from SYS when a valid
source is present at DC or USB. BAT powers SYS when neither DC nor USB power is present, or when the
SYS load exceeds the input current limit. Both BAT pins must be connected together externally.
Charger Status Output. Active-low, open-drain output pulls low when the battery is in fast-charge or
prequal. Otherwise, CHG is high impedance.
System Supply Output. SYS connects to BAT through an internal 50mΩ system load switch when DC or
USB are invalid, or when the SYS load is greater than the input current limit.
When a valid voltage is present at DC or USB, SYS is limited to V
exceeds the DC or USB current limit, SYS is regulated to 50mV below BAT, and both the powered input
and the battery service SYS.
Bypass SYS to GND with a 10μF (MAX8903A/MAX8903C/MAX8903D/MAX8903Y) or 22μF
(MAX8903B/MAX8903E/MAX8903G) X5R or X7R ceramic capacitor. Both SYS pins must be connected
together externally.
70mΩ Current-Sense Input. Connect the step-down inductor from LX to CS. When the step-down
regulator is on, there is a 70mΩ current-sense MOSFET from CS to SYS. When the step-down regulator is
off, the internal CS MOSFET turns off to block current from SYS back to DC.
Inductor Connection. Connect the inductor between LX and CS. Both LX pins must be connected together
externally.
Exposed Pad. Connect the exposed pad to GND. Connecting the exposed pad does not remove the
requirement for proper ground connections to the appropriate pins.
ISET
) from ISET to GND programs the fast-charge current up to 2A.
FUNCTION
Pin Description (continued)
SYSREG
. When the system load (I
SYS
)

Related parts for MAX8903GETI+