DS2141A Maxim Integrated Products, DS2141A Datasheet - Page 9

IC CONTROLLER T1 5V 40-DIP

DS2141A

Manufacturer Part Number
DS2141A
Description
IC CONTROLLER T1 5V 40-DIP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS2141A

Controller Type
T1 Controller
Interface
Parallel/Serial
Voltage - Supply
4.5 V ~ 5.5 V
Current - Supply
10mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Through Hole
Package / Case
40-DIP (0.600", 15.24mm)
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS2141A
Manufacturer:
2002+
Quantity:
6 219
Part Number:
DS2141AQ
Manufacturer:
DALLAS
Quantity:
5 510
Part Number:
DS2141AQ
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS2141AQ
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
DS2141AQ+
Manufacturer:
Maxim Integrated Products
Quantity:
135
Part Number:
DS2141AQ+
Manufacturer:
AM
Quantity:
34
Part Number:
DS2141AQ+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS2141AQ+T&R
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS2141AQ/T&R
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS2141AQN
Manufacturer:
Maxim Integrated
Quantity:
10 000
TCR1: TRANSMIT CONTROL REGISTER 1 (35h)
(MSB)
ODF
SYMBOL
TLINK
TYEL
TCPT
RBSE
GB7S
TFPT
ODF
TBL
TFPT
POSITION
TCR1.7
TCR1.6
TCR1.5
TCR1.4
TCR1.3
TCR1.2
TCR1.1
TCR1.0
TCPT
NAME AND DESCRIPTION
Output Data Format.
0=bipolar data at TPOS and TNEG.
1=NRZ data at TPOS; TNEG = 0.
Transmit Framing Pass Through.
0=Ft or FPS bits sourced internally.
1=Ft or FPS bits sampled at TSER during F-bit time.
Transmit CRC Pass Through.
0=source CRC6 bits internally.
1=CRC6 bits sampled at TSER during F-bit time.
Robbed Bit Signaling Enable.
0=no signaling is inserted in any channel.
1=signaling is inserted in all channels (the TTR registers can be
used to block insertion on a channel by channel basis).
Global Bit 7 Stuffing.
0=allow the TTR registers to determine which channels
containing all zeros are to be bit 7 stuffed.
1=force bit 7 stuffing in all zero byte channels regardless of how
the TTR registers are programmed.
TLINK Select.
0=source FDL or Fs bits from TFDL register.
1=source FDL or Fs bits from the TLINK pin.
Transmit Blue Alarm.
0=transmit data normally.
1=transmit an unframed all 1's code at TPOS and TNEG.
Transmit Yellow Alarm.
0=do not transmit yellow alarm.
1=transmit yellow alarm.
RBSE
9 of 39
GB7S
TLINK
TBL
(LSB)
TYEL
DS2141A

Related parts for DS2141A