ISP1761ET-S ST-Ericsson Inc, ISP1761ET-S Datasheet - Page 85

no-image

ISP1761ET-S

Manufacturer Part Number
ISP1761ET-S
Description
IC USB OTG CONTROLLER 128TFBGA
Manufacturer
ST-Ericsson Inc
Datasheet

Specifications of ISP1761ET-S

Controller Type
USB Peripheral Controller
Interface
Serial
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
128-TFBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Supply
-
Other names
568-3160

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ISP1761ET-S
Manufacturer:
ST-Ericsson Inc
Quantity:
10 000
NXP Semiconductors
Table 76.
ISP1761_5
Product data sheet
Bit
47
46
45 to 44
43 to 42
41 to 35
34 to 32
DW0
31
30 to 29
28 to 18
17 to 3
2 to 1
0
Symbol
reserved
S
EPType[1:0]
Token[1:0]
DeviceAddress
[6:0]
EndPt[3:1]
EndPt[0]
reserved
MaxPacket
Length[10:0]
NrBytesTo
Transfer[14:0]
reserved
V
Start and complete split for interrupt: bit description
Table 77.
Table 78.
b
5
6
7
8
9
Interrupt
I/O
I/O
Access
-
SW — writes
SW — writes
SW — writes
SW — writes
SW — writes
SW — writes
-
SW — writes
SW — writes
-
SW — sets
HW — resets
Microframe description
SE description
Value Description
-
-
-
-
-
-
-
-
-
-
-
-
S
1
0
Rev. 05 — 13 March 2008
-
This bit indicates whether a split transaction has to be executed:
0 — High-speed transaction
1 — Split transaction
Transaction type:
11 — Interrupt
Token PID for this transaction:
00 — OUT
01 — IN
Device Address: This is the USB address of the function containing
the endpoint that is referred to by this buffer.
Endpoint: This is the USB address of the endpoint within the function.
Endpoint: This is the USB address of the endpoint within the function.
-
Maximum Packet Length: This field indicates the maximum number
of bytes that can be sent to or received from an endpoint in a single
data packet. The maximum packet size for the full-speed and
low-speed devices is 64 bytes as defined in
Bus Specification Rev.
Number of Bytes to Transfer: This field indicates the number of bytes
that can be transferred by this data structure. It is used to indicate the
depth of the DATA field. The maximum total number of bytes for this
transaction is 4 kB.
-
0 — This bit is deactivated when the entire PTD is executed, or when a
fatal error is encountered.
1 — Software updates to one when there is payload to be sent or
received. The current PTD is active.
Rate
2 ms
4 ms
8 ms
16 ms
32 ms
…continued
E
0
0
2.0”.
Hi-Speed USB OTG controller
0 0001
0 0010 or 0 0011
0 0100 or 0 0111
0 1000 or 0 1111
1 0000 or 1 1111
Frame[7:3]
Ref. 1 “Universal Serial
Remarks
low-speed
full-speed
© NXP B.V. 2008. All rights reserved.
ISP1761
84 of 163