SY4S-05 IDEC Corporation, SY4S-05 Datasheet

no-image

SY4S-05

Manufacturer Part Number
SY4S-05
Description
Socket, Relay; 7A; 14-Blade; 4-Pole; DIN Rail Snap/Surface-Mount; M3 Screw Term
Manufacturer
IDEC Corporation
Type
Blader
Datasheet

Specifications of SY4S-05

Brand/series
SY Series
Current Rating
6 A
Current, Rating
7 A
Mounting
DIN Rail/Panel Surface
Mounting Type
DIN Rail Snap⁄Surface-Mount
Number Of Contacts
14
Number Of Poles
4
Receptacle Style
14-Blade
Relay Type
RU4S, RU42S, RY4S, RY42S, RY2KS, RY2LS, RM2S
Terminal Type
M3 Screw
Termination
Screw
Timer Type
GT5Y
Mating Relay Series
RY4S, RY42S, RU4S, RU42S, RM2S, *RY2KS (*latching relay)
Hold Down Spring
SY4S-51F1 for all relays;SY4S-51F3 for RY2KS only
Hold Down Clip
SFA-101 (top notch), SFA-202 (side notch) for all relays and timers
Contact Rating
6 A, 4PDT; 10 A, DPDT
Lead Free Status / Rohs Status
RoHS Compliant part

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SY4S-05D
Manufacturer:
IDEC
Quantity:
20 000
Section
F
for more information on this product family visit
www.idec.com/socket
• New and updated product information
• Downloadable software demos & upgrades
• Part configuration tool & cross reference
• Online stock check & ordering
• IDEC field sales & distributor search
• Online literature request
• Downloadable manuals & CAD drawings
• Manufacturer’s suggested retail price list
• Product training schedule & locations
• Advertising & trade show schedules
• Press releases & FAQs
Selection Guide.................................. F-2
Din Rail Snap/Surface-Mount
Sockets
Through Panel Mount Sockets
PCB Mount Sockets
Panel Mounted Sockets for Timers
Accessories ....................................... F-29
Dimensions....................................... F-31
Additional Web Resources
• SU Series . . . . . . . . . . . . . . . . . . . ..F-6
• SJ Series . . . . . . . . . . . . . . . . . . . . ..F-9
• SQ Series . . . . . . . . . . . . . . . . . . . F-10
• SR Series . . . . . . . . . . . . . . . . . . . F-11
• SH Series . . . . . . . . . . . . . . . . . . . F-14
• SY Series . . . . . . . . . . . . . . . . . . . F-18
• SM Series . . . . . . . . . . . . . . . . . . . F-20
• SR Series . . . . . . . . . . . . . . . . . . . F-21
• SH Series . . . . . . . . . . . . . . . . . . . F-22
• SY Series . . . . . . . . . . . . . . . . . . . F-24
• SH Series . . . . . . . . . . . . . . . . . . . F-25
• SY Series . . . . . . . . . . . . . . . . . . . F-26
• SR Series . . . . . . . . . . . . . . . . . . . F-28

Related parts for SY4S-05

SY4S-05 Summary of contents

Page 1

... SY Series . . . . . . . . . . . . . . . . . . . F-24 PCB Mount Sockets • SH Series . . . . . . . . . . . . . . . . . . . F-25 • SY Series . . . . . . . . . . . . . . . . . . . F-26 Panel Mounted Sockets for Timers • SR Series . . . . . . . . . . . . . . . . . . . F-28 Accessories ....................................... F-29 Dimensions....................................... F-31 for more information on this product family visit www.idec.com/socket Additional Web Resources • New and updated product information • ...

Page 2

... SH1B-05 1 5-Blade SH1B-05C SH2B-05 2 8-Blade SH2B-05C F-14 SH3B-05 3 11-Blade SH3B-05C SH4B-05 4 14-Blade SH4B-05C SY2S-05 2 8-Blade SY2S-05C F-18 SY4S-05 4 14-Blade SY4S-05C SM2S-05 F-20 2 8-Blade SM2S-05C SJ1S-05B 1 5-Blade SJ1S-07L F-9 SJ2S-05B 2 8-Blade SJ2S-07L SQ1V-07B 1 5-Blade F-10 SQ2V-07B 2 8-Blade SR2P-51 2 8-Pin F-21 SR3P-51 ...

Page 3

... Sockets SU, SR, SH, SM, SY Rated Insulation Voltage 300V; except SH1B, SU and SY4S-62: 250V SU2/SR/SH/SM: 10A, SY: 7A, SU4: 6A with RU4, Rated Current SU4: 10A with RU2 (SH1B: 7A) Insulation Resistance 100M minimum Dielectric Strength 2,000V AC, 1 minute Material Grade UL94V-0 3.5mm Screws, 9-11.5 in•lbs Terminal Torque 3mm screws, 5.5-9 in• ...

Page 4

... SH3B-05 RH3B, RH2LB SH3B-05C SH4B-05 RH4B SH4B-05C SY2S-05 RY2S, RY22S SY2S-05C RY4S, RY42S, RU4, RU42, SY4S-05 RM2S SY4S-05C RY2KS, GT5Y SM2S RM2S, RU2 SJ1S RQ1S SJ2S RJ2S SQ1S RQ1V SQ2S RQ2V 1. Hold-down springs work in conjunction with hold-down spring anchors included with DIN rail sockets. ...

Page 5

... SH4B-62 SY2S-51 RY2S, RY22S SY2S-61 RY4S, RY42S SY4S-51 SY4S-61 RY2KS GT5Y RY4S, RY42S, RM2S SY4S-62 * RY2KS * Does not accept hold down clips SFA-101 SFA-301 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Hold-Down Clip Hold-Down Pullover Spring (side latch) SR3P-01F1 — ...

Page 6

... Compatible Timer GT5Y-2 F Hold-Down Clip SFA-101 (top latch), SFA-202 (side latch the SU2S, wires or ferrules cannot be connected to terminals because neither springs nor conductive brackets are installed in these terminals. 2. For socket mounting accessories, see page F-29. Terminal Arrangement (top view) SU2S-11L SU4S-11L ...

Page 7

Sockets Applicable Wires Wire Stranded wire 0.2 to 1.25 mm Solid wire 0.2 to 1.5 mm Wire insulation diameter ø3.15mm maximum 1. Strip the wire insulation 9 to 10mm from the end applications using ferrules for stranded wires, ...

Page 8

SU Series: DIN Rail Snap-Mount SU Series: SU9Z-J5 Jumper Installation Instructions SU9Z-J5 Jumper for SU2S-11L and SU4S-11L The SU9Z-J5 is used to install five sockets. When installing less than five sockets cut the jumper according to the instructions listed to ...

Page 9

Sockets SJ1S-05B Style 5 -blade snap mount/surface mount Terminal/Torque 0.6 - 1.0N•m (Maximum 1.2N•m) Wire Size Maximum #14 AWG Electrical Rating 250V, 12A Compatible Relay RJ1S Compatible Timer N/A Hold-Down Spring N/A Replacement Locking Lever SJ9Z-C ...

Page 10

SJ/SQ Series: DIN Rail Snap-Mount SJ2S-07L Fingersafe Style 8-blade snap mount/surface mount Terminal/Torque 0.6 - 1.0N•m (Maximum 1.2N•m) Wire Size Maximum #14 AWG Electrical Rating 250V, 8A Compatible Relay RJ2S Compatible Timer N/A Hold-Down Spring N/A ...

Page 11

... RTE-P1, GT3 (8-pin), GT5P, GE1A Hold-Down Spring SR2B-02F1 (for RR2P) Hold-Down Clip SFA-202 (for timers only, except GE1A) 1. For socket mounting accessories, see page F-29. 2. For hold-down clip/spring selections, see page F-4. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC SR Series: DIN Rail Snap-Mount ...

Page 12

... RR3PA, *RR2KP (*latching relay) Compatible Timer GT3 (11-pin), RTE-P2 Hold-Down Spring SR3B-02F1 for RR3PA; SR3P-06F3 for RR2KP Hold-Down Clip SFA-202 (Timers) 1. For socket mounting accessories, see page F-29. 2. For hold-down clip/spring selections, see page F-4. www.idec.com F-12 Sockets SR3P Sockets 42 32 when ...

Page 13

... Compatible Timer RTE-B Hold-Down Spring SR3B-02F1 (relays) Hold-Down Clip SFA-202 (relays and timers) 1. For socket mounting accessories, see page F-29. 2. For hold-down clip/spring selections, see page F-4. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC SR Series: DIN Rail Snap-Mount SR3B Sockets ...

Page 14

... Electrical Rating 250V, 10A Compatible Relay RH1B Hold-Down Spring SY2S-02F1 Hold-Down Clip SFA-101 (top notch), SFA-202 (side notch) 1. For socket mounting accessories, see page F-29. 2. For hold-down clip/spring selections, see page F-4. www.idec.com F-14 SH Series: DIN Rail Snap-Mount Sockets SH1B Sockets ...

Page 15

... Maximum up to 2–#12AWG Electrical Rating 300V, 10A Compatible Relay RH2B Hold-Down Spring SY4S-02F1 Hold-Down Clip SFA-101 (top notch), SFA-202 (side notch) 1. For socket mounting accessories, see page F-29. 2. For hold-down clip/spring selections, see page F-4. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC ...

Page 16

... Electrical Rating 300V, 10A Compatible Relay RH3B, RH2LB Hold-Down Spring SH3B-05F1 Hold-Down Clip SFA-101 (top notch), SFA-202 (side notch) 1. For socket mounting accessories, see page F-29. 2. For hold-down clip/spring selections, see page F-4. www.idec.com F-16 Sockets SH3B Sockets 28.5 when using BAA ...

Page 17

... RH4B Hold-Down Spring SH4B-02F1 Hold-Down Clip SFA-101 (top notch), SFA-202 (side notch) 1. For socket mounting accessories, see page F-29. 2. For hold-down clip/spring selections, see page F-4. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC SH Series: DIN Rail Snap-Mount SH4B Sockets 28 ...

Page 18

... Electrical Rating 300V, 7A Compatible Relay RY2S, RY22S Hold-Down Spring SY2S-02F1 Hold-Down Clip SFA-101 (top notch), SFA-202 (side notch) 1. For socket mounting accessories, see page F-29. 2. For hold-down clip/spring selections, see page F-4. www.idec.com F-18 SY Series: DIN Rail Snap-Mount Sockets SY2S Sockets 17 6 ...

Page 19

... GT5Y SY4S-51F1 for all relays; SY4S-51F3 for Hold-Down Spring RY2KS only SFA-101 (top notch), SFA-202 (side Hold-Down Clip notch) for all relays and timers SY4S-05C Fingersafe Style 14-blade, snap-mount/surface mount M3 screw with captive wire clamp, Terminal/Torque fingersafe (5 in•lbs) Wire Size Maximum up to 2– ...

Page 20

... Maximum up to 2–#14AWG Electrical Rating 300V, 10A Compatible Relay RU2S, RM2S Compatible Timer — Hold-Down Spring SY4S-51F1 SFA-101 (top notch), SFA-202 (side Hold-Down Clip notch) 1. For socket mounting accessories, see page F-29. 2. For hold-down clip/spring selections, see page F-4. www.idec.com F-20 ...

Page 21

... SR3P-01F1 for RR3PA Hold-Down Spring SR3P-51F3 for RR2KP SFA-402 (for GT3 11-pin, Hold-Down Clip RTE-P2) 1. For socket mounting accessories, see page F-29. 2. For hold-down clip/spring selections, see page F-4. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC SR Series: Panel Mount Sockets 38 7 ...

Page 22

... Terminal Solder Electrical Rating 300V, 10A Compatible Relay RH2B SY4S-51F1 Hold-Down Spring SY4S-02F1 for RH2B-4C SFA-301 (top notch), Hold-Down Clip SFA-302 (side notch) 1. For socket mounting accessories, see page F-29. 2. For hold-down clip/spring selections, see page F-4. www.idec.com F-22 SH Series: Panel Mount Sockets ...

Page 23

... Style 11-blade, panel mount Terminal Solder Electrical Rating 300V, 10A RH3B, *RH2LB Compatible Relay (*latching relay) SY4S-51F1 Hold-Down Spring SY4S-02F1 for RH3B-4C SFA-301 (top notch), Hold-Down Clip SFA-302 (side notch) SH4B-51 Style 14-blade, panel mount Terminal Solder Electrical Rating 300V, 10A ...

Page 24

... RY2KS, RU4S, RU2S, RU42S Compatible Timer GT5Y SY4S-51F1 for all relays except; Hold-Down Spring SY4S-02F3 for RY2KS relay SFA-301 (top notch), Hold-Down Clip SFA-302 (side notch) 1. For socket mounting accessories, see page F-29. 2. For hold-down clip/spring selections, see page F-4. www.idec.com ...

Page 25

... Solder/PCB mount Electrical Rating 300V, 10A RH3B, *RH2LB Compatible Relay (*latching relay) Hold-Down Spring SY4S-51F1, SY4S-02F1 SFA-301 (top notch), Hold-Down Clip SFA-302 (side notch) 1. For socket mounting accessories, see page F-29. 2. For hold-down clip/spring selections, see page F-4. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC ...

Page 26

... SH/SY Series: PCB Mount SH4B-62 Style 14-blade Terminal Solder/ PCB mount Electrical Rating 300V, 10A Compatible Relay RH4B Hold-Down SY4S-51F1, SH4B-02F1 Springs SFA-301 (top notch), Hold-Down Clip SFA-302 (side notch) F SY2S-61 Style 8-blade Terminal Solder/PCB mount Electrical Rating 300V, 7A Compatible Relay ...

Page 27

... Solder/PCB mount Electrical Rating 300V, 7A RY4S, RY42S, RM2S, Compatible Relay *RY2KS, RU4S, RU42S, RU2S (*latching relay) Compatible Timer GT5Y Hold-Down Spring SY4S-51F1, SY4S-02F1 SFA-301 (top notch; except Hold-Down Clip GT5Y and RY2KS) SFA-302 (side notch for all) SY4S-62 Style 14-blade Terminal ...

Page 28

... Terminal M3.5 screws with captive wire clamp Electrical Rating 300V, 10A Wire Size Maximum up to 2-#12AWG Compatible Timer GT3 (8-pin), RTE-P1, GE1A Hold-Down Spring SY4S-02F1 F SR6P-M11G Style 11-pin Terminal M3.5 screws with captive wire clamp Electrical Rating 300V, 10A Wire Size ...

Page 29

... USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Accessories SA-203 M4 screw washer Use with All DIN rail sockets DIN rail SY2S, SY4S, SR3B, SH1B, SH2B, SH3B, SH4B SY2S, SY4S, SR3B, SH1B, SH2B, SH3B, SH4B All DIN rail sockets SY4S-51, SH2B-51 SY4S-51, SH2B-51 RH2B, RM2S, RY4S, RY42S, ...

Page 30

Instructions Mounting Snap-Mount Sockets Snap-mount sockets are designed to mount on the BNDN-1000 Mount mounting rail. The built-in mounting clip eliminates mounting hard- ware and reduces mounting time by 80%. To mount see Figure 1. Place the end of the ...

Page 31

... Figures 1 and 2). Use the SA-203 end connector at the outer ends of each socket row when using the SA-204 connector (see Figure 2). Dimension Table Socket Part No. Dim. B Dim. C SY2S-05, SY2S-05C 0.669" 0.826" SY4S-05, SY4S-05C 1.024" 1.181" SR3B-05 1.496" 1.693" SH1B-05, SH1B-05C 0.630" 0.787" SH2B-05, SH2B-05C 1.024" ...

Page 32

... SY2S- Total Overall Width of Each Socket Cutout – 0.221" (+ 0", – 0.020") SY2S-51 SY4S-51 SY4S-51 SY4S-51 SY2S- [0.709" + 1.063" + 1.063" + 0.709" + 1.063" + 0.709" + 1.063" + 1.063"] – 0.221" = 7.93" 7.93" (+ 0", – 0.020") USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Sockets Part No ...

Related keywords